Care, maintenance and disposal
General remarks
Under normal operating conditions, the wire-feed unit requires only a minimum of care and
maintenance. However, some important points must be noted to ensure that the welding
system remains in a usable condition for many years.
Every start-up
-
Check welding torch, interconnecting hosepack and ground earth connection for signs
of damage
-
Perform a visual check on the feed rollers and inner liners for signs of damage
-
Check contact pressure of feed rollers and adjust if necessary
-
Check brake and adjust if necessary
Every 6 months
-
Dismantle device side panels and clean inside of device with dry, reduced com-
pressed air
Disposal
Dispose of in accordance with the applicable national and local regulations.
WARNING!
An electric shock can be fatal. Before opening the device:
-
Move the mains switch to the O position
-
Unplug the device from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-
Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have been discharged
NOTE!
Risk of damage to electronic components. Do not bring the air nozzle too