31
EN
Pass the temperature-sensor cable and thermostat cable through the lead-through [J]
(not illustrated) in the interior compartment
Connect up the litz wires of the temperature-sensor cable and the thermostat cable to
the operating panel [E] as shown in the circuit diagram.
Lower the operating panel [E] into place
Mount the operating panel [E] - “Extrude-Tide“ screws (1)
Putting the interi
-
or heating system
into service
Plug in the mains plug
Set the desired temperature
For a description of the operating panel for the interior heating system, please see the en
-
closed Operating Instructions for the thermostat
Technical data:
24 V interior heat
-
ing system, regu
-
lated
Factory configuration of the control unit
(1)
(1)
1
2
3
4
1
2
Mains voltage
230 V
Mains frequency
50 / 60 Hz
Operating voltage of heating system
27 V
Rated output
550 W
Inside lighting
24 V / 10 W
Sensor selection
SEnS:
810
Input range, min.
rLO:
-20 °C
Input range, max.
rHi:
80 °C
Output selection
OUtS:
0.120
Alternating set-point selection
SPS:
1
Alarm-type, Alarm 1
ALIt:
PLd
Control selection
CntL:
r o