103
EN
no | Prg
Cause:
No preconfigured program has been selected
Remedy:
Select a configured program
no | IGn
Cause:
"Ignition time out" function is active; no current started flowing before the
length of wire specified in the set-up menu had been fed. The power source
safety cut-out has tripped.
Remedy:
Shorten the wire end; press the torch trigger again; clean the surface of the
workpiece; if necessary, increase the wire length until the safety cut-out trips
in "Set-up menu: Level 2".
EPG | 17
Cause:
The welding program selected is invalid
Remedy:
Select valid welding program
EPG | 29
Cause:
The required wire-feed unit is not available for the selected characteristic
Remedy:
Connect correct wire-feed unit, check plug connections for the hosepack
EPG | 35
Cause:
Measurement of the welding circuit resistance "r" failed
Remedy:
Check grounding cable, current cable or hosepack and replace if necessary,
recalculate welding circuit resistance "r"
no | GAS
Cause:
The Gas watchdog option has detected that there is no gas pressure
Remedy:
Connect a new gas cylinder or open the gas cylinder valve/pressure regulator,
restart "Gas watchdog" option, reset "no | GAS" error message by pressing
any button.
Summary of Contents for VR 5000 noSpool
Page 2: ...2...
Page 4: ...4...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 41: ...Installation and commissioning...
Page 42: ......
Page 51: ...51 EN 1 2 1 2...
Page 58: ...58...
Page 59: ...Welding...
Page 60: ......
Page 76: ...76 Number 3 Number 4 Number 5...
Page 77: ...Setup settings...
Page 78: ......
Page 92: ...92...
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...Technical data and settings tables...
Page 106: ......
Page 123: ...Appendix...
Page 125: ...125...
Page 127: ...127 8 8 8 8 5 5 5 Motor Plate Alu 4R s Connector Motor...
Page 128: ...128...
Page 129: ...129...
Page 130: ...130...
Page 131: ...131...