28
Manual control panel
General
The control panel allows straightforward manual setting of the welding parameters.
Manual control
panel
No.
Function
(1)
"Process" button
*)
for selecting the welding process
MIG/MAG welding
STICK manual metal arc welding
for selecting welding parameters in the Setup menu
(2)
"Mode" button
for selecting the operating mode
2-step mode
4-step mode
for selecting welding parameters in the Setup menu
(3)
Welding voltage adjuster
for selecting the welding voltage in V
The welding voltage is directly related to the arc length.
(4)
Wire feed speed adjuster
for selecting the wire feed speed in m/min or ipm.
If the welding voltage (3) remains constant, the welding current increases as the
wire feed speed (4) increases
(6)
(5)
(5)
(4)
(3)
(2)
(1)
Summary of Contents for VR 5000 noSpool
Page 2: ...2...
Page 4: ...4...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 41: ...Installation and commissioning...
Page 42: ......
Page 51: ...51 EN 1 2 1 2...
Page 58: ...58...
Page 59: ...Welding...
Page 60: ......
Page 76: ...76 Number 3 Number 4 Number 5...
Page 77: ...Setup settings...
Page 78: ......
Page 92: ...92...
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...Technical data and settings tables...
Page 106: ......
Page 123: ...Appendix...
Page 125: ...125...
Page 127: ...127 8 8 8 8 5 5 5 Motor Plate Alu 4R s Connector Motor...
Page 128: ...128...
Page 129: ...129...
Page 130: ...130...
Page 131: ...131...