36
(2)
"Wire diameter" button
For selecting the wire diameter to be used. Welding parameter SP is reserved for
additional wire diameters.
When a wire diameter is selected, the LED behind the relevant wire diameter lights
up.
(3)
"Shielding gas" button
For selecting the shielding gas to be used. Welding parameter SP is reserved for
additional shielding gases.
When a shielding gas is selected, the LED behind the relevant shielding gas lights
up.
Keylock
A keylock can be selected to prevent the settings from being inadvertently changed on the
control panel. As long as the keylock is active
-
no settings can be made on the control panel
-
only parameter settings can be retrieved
-
any assigned "Save" button can be retrieved provided that an assigned "Save" button
was selected when the keylock was enabled
Activate/deactivate the keylock as follows:
Keylock activated:
The message "CLO | SEd" appears on the displays.
Keylock deactivated:
The message "OP | En" appears on the displays.
Service parame-
ters
Various service parameters can be retrieved by pressing the "Parameter selection" buttons
at the same time.
Opening the display
The first parameter ("Firmware version") is displayed, e.g. "1.00 | 4.21"
Selecting parameters
Press and hold the "Mode" button
Press the "Parameter selection" button (right)
Release the "Mode" and "Parameter Selection" buttons
1
2
3
Press and hold the "Parameter selection" button (left)
Press the "Parameter selection" button (right)
Release the "Parameter selection" buttons
Select the required setup parameter using the "Mode" and "Pro-
cess" buttons or the left-hand adjusting dial
1
2
3
1
Summary of Contents for VR 5000 noSpool
Page 2: ...2...
Page 4: ...4...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 41: ...Installation and commissioning...
Page 42: ......
Page 51: ...51 EN 1 2 1 2...
Page 58: ...58...
Page 59: ...Welding...
Page 60: ......
Page 76: ...76 Number 3 Number 4 Number 5...
Page 77: ...Setup settings...
Page 78: ......
Page 92: ...92...
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...Technical data and settings tables...
Page 106: ......
Page 123: ...Appendix...
Page 125: ...125...
Page 127: ...127 8 8 8 8 5 5 5 Motor Plate Alu 4R s Connector Motor...
Page 128: ...128...
Page 129: ...129...
Page 130: ...130...
Page 131: ...131...