85
EN
Welding parame-
ters for "Special
4-step mode" in
the Mode setup
menu
I-S
I (current) - Starting: Starting current
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 100
SL
Slope: 0 - 9.9 s
Unit: s
Setting range: 0 - 9.9
Factory setting: 0
I-E
I (current) - End: Final current
Unit: % of welding current
Setting range: 0 - 200
Factory setting: 50