95
EN
Troubleshooting
General
The devices are equipped with an intelligent safety system. This means that to a large ex-
tent it has been possible to dispense with melting-type fuses. Melting-type fuses therefore
no longer need to be replaced. After a possible malfunction has been remedied, the device
is ready for use again.
Safety
WARNING!
Work that is carried out incorrectly can cause serious injury or damage.
The following activities must only be carried out by trained and qualified personnel. Read
the safety rules in the wire-feed unit operating instructions.
WARNING!
An electric shock can be fatal.
Before opening the unit
► Turn the mains switch to the "O" position
► Unplug the device from the mains
► Put up an easy-to-understand warning sign to stop anybody inadvertently switching it
back on again
► Using a suitable measuring device, check to make sure that electrically charged com-
ponents (e.g. capacitors) have discharged
CAUTION!
Inadequate PE conductor connections can cause serious injury and damage.
The housing screws provide a suitable PE conductor connection for earthing (grounding)
the housing and must NOT be replaced by any other screws which do not provide a reliable
PE conductor connection.
Fault diagnosis
Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
-
errors occur that are not listed below
-
the troubleshooting measures listed are unsuccessful
Power source has no function
Mains switch is on, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged in
Remedy:
Check the mains lead, ensure that the mains plug is plugged in
Cause:
Mains socket or mains plug faulty
Remedy:
Replace faulty parts
Cause:
Mains fuse protection
Remedy:
Change the mains fuse protection
Summary of Contents for VR 5000 noSpool
Page 2: ...2...
Page 4: ...4...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 41: ...Installation and commissioning...
Page 42: ......
Page 51: ...51 EN 1 2 1 2...
Page 58: ...58...
Page 59: ...Welding...
Page 60: ......
Page 76: ...76 Number 3 Number 4 Number 5...
Page 77: ...Setup settings...
Page 78: ......
Page 92: ...92...
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...Technical data and settings tables...
Page 106: ......
Page 123: ...Appendix...
Page 125: ...125...
Page 127: ...127 8 8 8 8 5 5 5 Motor Plate Alu 4R s Connector Motor...
Page 128: ...128...
Page 129: ...129...
Page 130: ...130...
Page 131: ...131...