Drive system faulty
Torque mode:
Motor does not reach the specified feed force
-
Wire end
-
Contact-pressure lever open
-
Insufficient contact pressure
Threading mode:
-
Feed rollers blocked
-
Encoder fault
The signal can be reset by pressing the Mode / Start button.
Overtemperature on SR63 power module board
The signal can be reset by pressing the Mode / Start button.
Drive system faulty
-
Motor is not recognised
or
-
CFM motor fault
Turn the device off and on again to reset the signal.
The unreeling wirefeeder was unable to complete automatic determination
of the rotor position
(e.g. the QuickConnect WireBrake option was closed while determining the
rotor position)
The signal can be reset using the OFF / ON switches on the device.
Another attempt is made to determine the rotor position.
Fault on SR63 PC board
(internal SR63 fault)
Fault diagnosis
Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
-
errors occur that are not listed below
-
the troubleshooting measures listed are unsuccessful
Unreeling wire-feed unit not working
Mains switch is on, but indicators are not lit up
Cause
There is a break in the mains cable; the mains plug is not
plugged in
Remedy
Check the mains cable, ensure that the mains plug is plugged
in
Cause
Mains socket or mains plug faulty
36