Inserting/replacing feed rollers
Safety
WARNING!
An electric shock can be fatal.
If the power source is connected to the mains supply while the work described below is
being carried out, there is a high risk of very serious injury and damage. Only carry out
the work described below when:
▶
the power source mains switch is in the "O" position
▶
the power source is unplugged from the mains
▶
all system components are disconnected from the mains
General
The feed rollers are not installed in the device when it is first delivered.
In order to achieve optimum wire electrode feed, the feed rollers must be suitable for the
diameter and alloy of the wire being welded.
NOTE!
Risk from inadequate feed rollers.
This can result in poor weld properties.
▶
Only use feed rollers that match the wire electrode.
An overview of the feed rollers available and their possible areas of use can be found in
the Spare Parts Lists.
2-roller drive:
Inserting/repla-
cing feed rollers
1
2
CAUTION!
Risk of crushing due to exposed feed rollers.
▶
Always fit the protective cover of the 2-roller drive after changing feed rollers.
26