COMPLIANCE 

DECLARATION OF CONFORMITY 

FROST ITALY s.r.l. 

Via Lago di Trasimeno, 46 

36015-Schio (VI)- Italy 

 

For 

FROST ITALY 

 

ULYSSE UNIT: 

                                              MAKE     : FROST ITALY 
                                              SERIES   : ULYSSE  

                          MODEL   :  400/600/1000/1500/ 

                                         2000/2500/3000/3600 

 

Are complying at: 

Machine Directive 98/37/CEE; 

Directive PED 97/23/CE. Module D1; 

Electromagnetic Compatibility Directive 89/336/CEE; 

CONFORMITA’

 

 

DICHIARAZIONE DI CONFORMITA’ 

 

FROST ITALY s.r.l. 

Via Lago di Trasimeno, 46 

36015-Schio (VI) 

 

Per la

 FROST ITALY 

 

L’unità ULYSSE 

        MARCA        : FROST ITALY 

                                           SERIE          : ULYSSE HP 
                                           MODELLO   :  400/600/1000/1500/ 
                                                               2000/2500/3000/3600 

 

Sono conformi a: 

Direttiva Macchine 98/37/CEE; 

Direttiva PED 97/23/CE. Modulo D1; 

Direttiva Compatibilità Elettromagnetica 89/336/CEE; 

 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ULYSSE 1000

Page 1: ...y Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 1 Recuperatori di calore Heat recovery units ULYSSE MANUALE DI INSTALLAZIONE E MANUTENZIONE INSTALLATION AND MAINTENENCE MANUAL LEGGI E...

Page 2: ...0 600 1000 1500 2000 2500 3000 3600 Are complying at Machine Directive 98 37 CEE Directive PED 97 23 CE Module D1 Electromagnetic Compatibility Directive 89 336 CEE CONFORMITA DICHIARAZIONE DI CONFORM...

Page 3: ...ALE SONO UTILIZZATI SIMBOLI DAL SEGUENTE SIGNIFICATO IN THIS MANUAL WILL BE USED SOME SYMBOLS LIKE THE FOLLOWING ATTENZIONE per azioni che richiedono particolare cautela ed adeguata preparazione ATTEN...

Page 4: ...bale d avviamento La documentazione fornita con l unit deve essere consegnata al proprietario affinch la conservi con cura per eventuali manutenzioni o assistenze GENERAL INSTRUCTIONS Before proceed t...

Page 5: ...tected room from the bad weather with temperatures included between the 20 C and the 55 C MOVIMENTAZIONE DELL UNITA HANDLING OF THE UNIT Le unit FROST ITALY possono essere movimentate sia con carrelli...

Page 6: ...eguito Raising with crane To use a balance or a forked bars Suitably sturdy rope or straps avoid the use of chains Protections to install among strap and machine to avoid that the structure ruins itse...

Page 7: ...n the unit and the other equipment or adjacent structures must be observed In this way the air will be free to circulate and will allow a correct operation from side of the unit and it will be possibl...

Page 8: ...36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 8 SCHEMA INSTALLAZIONE A SOFFITTO ROOF INSTALLATION SCHEME 1 0 N 4 SCREW LOCKNUT ISOLATOR SCHEMA INSTALLAZIONE A...

Page 9: ...re negli appositi fori ricavati nei piedini d appoggio dei supporti antivibranti seguendo lo schema indicato di seguito Rubber anti vibrating dampers At the end to avoid the transmission of vibrations...

Page 10: ...HP DIMENTIONAL DRAWING ULYSSE HP RIPRESA ARIA INTERNA A1 SUCTION INDOOR AIR ESPULSIONE ARIA INTERNA A2 INDOOR AIR EXPULSION INGRESSO ARIA RINNOVO B1 INLET RENEWAL AIR MANDATA ARIA RINNOVO B2 DELIVERY...

Page 11: ...prevenire l entrata di odori ed insetti The drainage system should features and adequately sized siphon to ensure free condensate drainage prevent the inadvertent entry of air into the circuit under...

Page 12: ...ione portare il cavo di alimentazione al quadro elettrico all interno dell unit Collegarsi all interruttore rispettando la fasi L il neutro N la terra PE nel caso di alimentazione monofase con neutro...

Page 13: ...connessioni dei conduttori d alimentazione ed il loro stato Verificare il collegamento a terra Verificare il collegamento remoto se installato o la presenza dei ponti sui morsetti ATTENTION Before st...

Page 14: ...lamping state of the connection clamps of the electric power cables and of signal Supervised by the authorized assistance centre To verify that the values of voltage re enter in the described values t...

Page 15: ...0 95 0 82 0 82 Corrente assorbita 1 Input current A 2 9 4 5 4 4 Potenza frigorifera recuperata 1 Recovery cooling capacity kW 0 5 0 7 1 2 1 8 Efficienza recuperatore 1 Recovery efficiency 46 7 44 8 4...

Page 16: ...ecuperata 2 Recovery heating capacity kW 8 0 9 7 11 7 14 0 Efficienza recuperatore 2 Recovery efficiency 47 7 46 3 46 6 46 6 Temperatura di uscita dell aria 2 Outlet air temperature C 6 9 6 6 6 6 6 7...

Page 17: ...se contact the energy supplying agency Check the clamping state of the connection clamps of the electrical board in particular the connection clamps for the compressor automatic switch and control swi...

Page 18: ...FROST ITALY s r l Via Trasimeno 46 int 1 Z I 36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 18...