background image

 

FROST ITALY s.r.l.

 -Via Trasimeno 46-int.1 – Z.I. – 36015 Schio – Vicenza – Italy 

Tel. +39/+445/576772 – Fax +39/+445/576775 – e-mail info@frostitaly.it

 

3

 

GARANZIA

 

WARRANTY

 

climatizzatori 

della 

FROST 

ITALY 

godono  di  una  GARANZIA  SPECIFICA, 
secondo  normativa  europea,  che  decorre 
dalla  data  di  acquisto  dell’apparecchio  e  
che  l’utente  è  tenuto  a  documentare;  nel 
caso non sia in grado di farlo, la garanzia 
decorrerà  dalla  data  di  fabbricazione 
dell’apparecchio.

 

The units produced by FROST ITALY have a 
SPECIFIC  WARRANTY  (in  accordance  with 
the european regulation) starting from the 
selling    date  that  has  to  be  proved  by  the 
user. In the case the user cannot show any 
documentation  the  warranty  will  start 
from the manufacturing date.

 

 
 

IN ALCUNE PARTI DEL MANUALE 

SONO UTILIZZATI SIMBOLI DAL 

SEGUENTE SIGNIFICATO: 

IN THIS MANUAL WILL BE USED 

SOME SYMBOLS LIKE  

THE FOLLOWING:

 

 

ATTENZIONE

 = per azioni che richiedono particolare cautela ed adeguata 

preparazione 

ATTENTION

= for actions that can be done only by qualified persons

 

VIETATO

 = per azioni che 

NON DEVONO

 essere assolutamente eseguite 

FORBIDDEN =

 for actions that HAVE ABSOLUTELY NEVER TO BE DONE. 

 
 

ATTENZIONE 

OBBLIGO MONTAGGIO SIFONE SULLO 

SCARICO ACQUA DI CONDENSA 

IN CASO DI ASSENZA LA 

FROST ITALY DECLINA OGNI 

RESPONSABILITA’ SU EVENTUALI DANNI 

 

     ATTENTION

 

THE SIPHON INSTALLATION ON 

DISCHARGE CONDENSATE WATER IS 

COMPULSORY. 

OTHERWISE THE FROST ITALY DOESN’T 

ASSUME ANY LIABILITY FOR POSSIBLE 

CONSEQUENTLY DAMAGES 

 

ATTENZIONE 

VERIFICARE CHE LA CORRENTE ASSORBITA 

DAI VENTILATORI SIA INFERIORE AL 

VALORE DI TARGA RIPORTATO NEI DATI 

TECNICI. 

 

ATTENTION

 

VERIFY THE ADSORBED CURRENT OF 

FANS, IS LESS THAN THE NOMINAL 

CURRENT READ IN THE TECHNICAL 

DATA. 

 
 
 
 
 
 
 

Summary of Contents for ULYSSE HP 1000

Page 1: ...5 576775 e mail info frostitaly it 1 Recuperatori di calore con pompa di calore integrata Heat recovery units with integrated heat pump ULYSSE HP MANUALE DI INSTALLAZIONE E MANUTENZIONE INSTALLATION A...

Page 2: ...0 1000 1500 2000 2500 3000 3600 5000 Are complying at Machine Directive 98 37 CEE Directive PED 97 23 CE Module D1 Electromagnetic Compatibility Directive 89 336 CEE CONFORMITA DICHIARAZIONE DI CONFOR...

Page 3: ...ALE SONO UTILIZZATI SIMBOLI DAL SEGUENTE SIGNIFICATO IN THIS MANUAL WILL BE USED SOME SYMBOLS LIKE THE FOLLOWING ATTENZIONE per azioni che richiedono particolare cautela ed adeguata preparazione ATTEN...

Page 4: ...rbale d avviamento La documentazione fornita con l unit deve essere consegnata al proprietario affinch la conservi con cura per eventuali manutenzioni o assistenze GENERAL INSTRUCTIONS Before proceed...

Page 5: ...tected room from the bad weather with temperatures included between the 20 C and the 55 C MOVIMENTAZIONE DELL UNITA HANDLING OF THE UNIT Le unit FROST ITALY possono essere movimentate sia con carrelli...

Page 6: ...eguito Raising with crane To use a balance or a forked bars Suitably sturdy rope or straps avoid the use of chains Protections to install among strap and machine to avoid that the structure ruins itse...

Page 7: ...n the unit and the other equipment or adjacent structures must be observed In this way the air will be free to circulate and will allow a correct operation from side of the unit and it will be possibl...

Page 8: ...36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 8 SCHEMA INSTALLAZIONE A SOFFITTO ROOF INSTALLATION SCHEME 1 0 N 4 SCREW LOCKNUT ISOLATOR SCHEMA INSTALLAZIONE A...

Page 9: ...re negli appositi fori ricavati nei piedini d appoggio dei supporti antivibranti seguendo lo schema indicato di seguito Rubber anti vibrating dampers At the end to avoid the transmission of vibrations...

Page 10: ...NG ULYSSE HP RIPRESA ARIA INTERNA A1 SUCTION INDOOR AIR ESPULSIONE ARIA INTERNA A2 INDOOR AIR EXPULSION INGRESSO ARIA RINNOVO B1 INLET RENEWAL AIR MANDATA ARIA RINNOVO B2 DELIVERY RENEWAL AIR Modello...

Page 11: ...prevenire l entrata di odori ed insetti The drainage system should features and adequately sized siphon to ensure free condensate drainage prevent the inadvertent entry of air into the circuit under...

Page 12: ...Tutte le unit FROST ITALY sono predisposte per il controllo e il monitoraggio remoto della macchina Per ricavarsi il numero dei morsetti per il collegamento remoto fare riferimento allo schema elettr...

Page 13: ...ID3 12 ID4 10 13 ID1 14 ID2 Il terminale remoto fornito assieme all unit Utilizzare un cavo schermato bi polare da 1 5mm2 per collegare i morsetti 88 89 con il terminale remoto The remote display is e...

Page 14: ...a tolerance of the 10 of the nominal tension of power supply of the unit indicated on the panel of the electrical board 230V 10 To verify the connections of the conductors of power supply and their s...

Page 15: ...livello di rumorosit del compressore non sia superiore al normale e che la pressione di mandata sia superiore alla pressione di aspirazione in caso contrario controllare la sequenza delle fasi di ali...

Page 16: ...azione dell unit Controllare lo stato di serraggio dei morsetti di connessione dei cavi elettrici di potenza e di segnale Cura del centro assistenza autorizzato Verificare che i valori di tensione rie...

Page 17: ...essere eseguita da personale frigorista specializzato Il fluido frigorigeno e l olio lubrificante contenuti nel circuito dovranno essere recuperati in accordo con le norme vigenti nel Vostro Paese The...

Page 18: ...otenzialit riscaldamento recuperata 2 Recovery heating capacity kW 1 75 2 50 4 10 6 90 8 90 Efficienza recuperatore 2 Recovery efficiency 51 8 49 6 49 0 54 8 52 9 Temperatura di uscita dell aria 2 Out...

Page 19: ...calore 1 Heat pump cooling capacity kW 4 80 5 00 5 50 8 00 Potenza frigorifera totale 1 Total cooling capacity kW 7 60 8 40 9 80 13 0 Temperatura di uscita dell aria 1 Outlet air temperature C 28 7 2...

Page 20: ...the safety guard and in the air space Check the correct wiring of the electrical supply if it is three phase respect the correct position of the neutral and the phases CONTROLLI MENSILI MONTHLY CONTR...

Page 21: ...FROST ITALY s r l Via Trasimeno 46 int 1 Z I 36015 Schio Vicenza Italy Tel 39 445 576772 Fax 39 445 576775 e mail info frostitaly it 21...

Reviews: