6 Power Connection
31
6.3
Power Connection
The horstCONTROL power connection is a standard IEC C14 male socket (IEC-60320) with integrated
pull-out protection. The supplied power cable has a safety plug at one end and an IEC C13 cold-device
coupling with specially molded housing at the other end. This, together with the pull-out protection, en-
sures reliable connection to the power supply. Therefore, always used the power cable supplied.
The power supply must have:
−
Main fuse
−
Circuit breaker
−
Ground connection (PE protective conductor)
.
The horstCONTROL is equipped with a power entry filter and a 6.3 A fuse.
Connect the horstCONTROL to the
power supply with the supplied power
cable. Lay the power cable such that
it is protected against damage.
Fig. 6-3:
Power connection to horstCONTROL
Parameter
min.
typ.
max.
Unit
Input voltage
90
-
260
VAC
Input frequency
47
-
63
Hz
Current consumption
4.4
A
Rated power draw
(1)
300
W
Table 6-1: Mains connection characteristic values
(1)
Power draw measuring conditions: horstCONTROL PCB/PCC, Robot H900, all axes moved at the same time,
speed 100%, load capacity 0 kg, measuring period 2 hours
ELECTRICAL VOLTAGE!
Ensure that all cables are connected correctly before supplying the horstCONTROL
with power. Always use the original power cable supplied.
Make sure that the robot is grounded (power plug connected to PE protective con-
ductor).
A suitable circuit breaker and a suitable RCD (residual current operated device)
must be installed.
Summary of Contents for HORST900