background image

9

APPLICATION EXAMPLES

MAINS INPUT

SERIAL:

117 V

SPKR OUT

LIFT

GROUND

POWER STATION MODEL PS-100

STEVEN FRYETTE DESIGN, INC.

AMP IN

IMPEDANCE

SELECT

LINE OUT

BALANCED

SPEAKER

2/4

8

16

2/4

8

16

200W

MAX

FT SW

AMPLIFIER

FX SEND

LINE IN

FX RETN

FX

LEVEL

LINE OUT

FUSE

MAIN

T4A

50/60 HZ

300 WATTS

AVIS: RISQUES DE CHOC ELECTRIQUE, NE PAS OUVRIR:

WARNING: HAZARDOUS VOLTAGE INSIDE. REFER

SERVICING TO QUALIFIED SERVICE PERSONNEL:

CAUTION: DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE:

CAUTION REPLACE ONLY

WITH SAME TYPE FUSE

UTILISER UN FUSIBLE DE

ECHANGE DE MEME TYPE

REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL

NO USER SERVICABLE PARTS INSIDE

LINE

LEVEL

HI

LO

to input 

on mixer

from PS100

FX loop

to PS100 FX loop

to PS100 line in

PS100 spkr out to  cab in / 8 Ω

to input 

on mixer

F

5. David Torn type setup for live performance and/or recording.

Power Station

OPERATE

VOLUME

PRESENCE

DEPTH

BYPASS

POWER

ON

Variable Reactive Load + Vacuum Tube Power PS-100

EDGE

SELECT

FLAT

BRITE

DEEP

LEVEL

FLAT

WARM

®

HI

LO

Dual-Mode Reactance Amplifier

MAINS INPUT

SERIAL:

117 V

SPKR OUT

LIFT

GROUND

POWER STATION MODEL PS-100

STEVEN FRYETTE DESIGN, INC.

AMP IN

IMPEDANCE

SELECT

LINE OUT

BALANCED

SPEAKER

2/4

8

16

2/4

8

16

200W

MAX

FT SW

AMPLIFIER

FX SEND

LINE IN

FX RETN

FX

LEVEL

LINE OUT

FUSE

MAIN

T4A

50/60 HZ

300 WATTS

AVIS: RISQUES DE CHOC ELECTRIQUE, NE PAS OUVRIR:

WARNING: HAZARDOUS VOLTAGE INSIDE. REFER

SERVICING TO QUALIFIED SERVICE PERSONNEL:

CAUTION: DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE:

CAUTION REPLACE ONLY

WITH SAME TYPE FUSE

UTILISER UN FUSIBLE DE

ECHANGE DE MEME TYPE

REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL

NO USER SERVICABLE PARTS INSIDE

LINE

LEVEL

HI

LO

Amp Speaker Out

All red outlined functions operate without power

No A/C power needed

XLR Line Out

to mixer

Standard ¼“ to ¼“

male speaker cable

4. Silent mode.

USING SILENT MODE

WHEN USING A HIGH-POWERED AMP 

CRANKED, YOU MUST RUN THE POWER 

STATION WITH THE AC CORD PLUGGED IN 

AND THE POWER SWITCH TURNED ON. 

IN THIS CASE, LEAVE THE OPRATE/BYPASS 

SWITCH SET TO BYPASS.

Silent Mode allows you to use the Power 
Station as a silent adjustable reactive load 
for quiet direct recording or when sending 
a live amp signal to front of house with no 
speaker cab connected. In this mode it is not 
necessary to power up the Power Station. 
You don’t even need to plug in the power 
cord. The Voicing switches, FX Send (along

CAUTION! The 200W maximum power ra-
ting of the Power Station’s load depends 
on the fan being operational. Running the 
Power Station with no AC power disables 
the fan and the Maximum Power rating is 
reduced by 50%.

with the FX Level switch), Line Out, Line Level
control and the Balanced and Unbalanced
Line Outputs all operate with no AC power 
supplied.

Summary of Contents for Power Station 100

Page 1: ...Power Station OWNERS MANUAL DUAL MODE VARIABLE REACTIVE LOAD TUBE POWER AMPLIFIER MODEL PS 100 www fryette com...

Page 2: ...t the natural interaction between the speaker and power tube stage of your amplifier causing an artificial compressed sound and stiff feel The PS 100 is a 100 watt version of the award winning PowerSt...

Page 3: ...en dropped or the enclosure damaged X X Do not drip or splash liquids nor place liquid filled containers on the unit X X CAUTION No user serviceable parts inside refer servicing to qualified personnel...

Page 4: ...ttle more low end projection in your live or recorded mix NOTE These switches only operate when your load amplifier s speaker output is connected to the Power Station Amp In jack They remain operation...

Page 5: ...nd jack for use with external effects processor This connec tion is post AMP IN and LINE IN so any effect connected here will be inserted between your load remotely engaged or bypassed with a footswit...

Page 6: ...d the load amplifier connected to the AMP IN jack Select the position which yields quietest operation With a properly wired AC outlet and factory supplied AC cord this switch may not produce a noticea...

Page 7: ...ED SERVICE PERSONNEL NO USER SERVICABLE PARTS INSIDE LINE LEVEL HI LO Amp Speaker Out Speaker Cab In XLR Line Out to mixer Standard to male speaker cable 1 Amp head to Power Station to Cab with effect...

Page 8: ...mp Speaker Cab In Preamp Out to Line In 3 Preamp to Power Station Line In effect in loop and Power Station speaker out to speaker MAINS INPUT SERIAL 117 V SPKR OUT LIFT GROUND POWER STATION MODEL PS 1...

Page 9: ...INE OUT FUSE MAIN T4A 50 60 HZ 300 WATTS AVIS RISQUES DE CHOC ELECTRIQUE NE PAS OUVRIR WARNING HAZARDOUS VOLTAGE INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION DO NOT EXPOSE THIS EQUIPM...

Page 10: ...nd and return cables are good and properly connected 2 Check footswitch remote switcher cable TRS RUNNING HOT 1 Make sure that the unit has adequate ventilation 2 Make sure that the impedance selector...

Page 11: ...tive EC1907 206 for the Registration Evaluation Authorization and Restriction of chemicals REACh and contain none or less than 0 1 of the chemicals listed as hazardous chemicals in the REACh regulatio...

Page 12: ...FD including but not limited to any malfunction defects or failure caused by or resulting from unauthorized service or parts damaged or broken tubes incorrect line voltage improper maintenance modific...

Reviews: