7-4
7.
Reinstall the back panel and element housing to complete the installation, then reverse steps 1
and 2 to return the fryer to service.
7.5
Replacing a Heating Element
1.
Perform steps 1-3 of section 7.4,
Replacing a Temperature Probe or High-Limit Thermostat
.
2.
Locate and disconnect connector C7. Using a pin pusher (Frymaster P/N
), push out the
red and white leads.
3.
On the rear of the contactor box, disconnect the 6-pin and 9-pin connectors.
4.
Remove the nuts and machine screws that secure the element assembly to the frypot and lift the
assembly out of the frypot. Remove the screws from the appropriate element clamps to separate
the element being replaced from the assembly.
5.
If the element with the probe is being replaced, recover the probe bracket and probe from the
element and install them on the replacement element. Install the replacement element in the
assembly using the screws and clamps removed in step 4. Reattach the assembly to the frypot
using the original mounting screws and nuts.
6.
Press in on the tabs on each side of the connector of the failed element while pulling outward on
the free end to extend the connector and release the element leads (see photo below). Pull the
leads out of the connector.
7.
Press the pins of the replacement element into the connector in accordance with the diagram
below, then close the connector to lock the leads in place.
1
4
2
5
3
6
1
4
2
5
3
6
7
8
9
5R 4R
6R
1R
2R
3R
Pip marks Position 1
5L
4L
6L
1L
2L
3L