Summary of Contents for 116526

Page 1: ...ICK SHAKER Installation and Operation Manual English Version 1 01 September 2016 COD 118576 737NG STICK SHAKER CPT NO PSU COD 237591 737NG STICK SHAKER CPT PSU COD 116526 737NG STICK SHAKER CPT FO PSU ME137437 ...

Page 2: ......

Page 3: ...er 1 Overview 1 1 Features and requirements 4 Chapter 2 Installation 2 1 Hardware installation and setup 6 2 2 Configuring USB Connection 7 2 3 Configuring LAN Connection 8 Chapter 3 Operation 3 1 Operating the Stick Shaker 12 ...

Page 4: ...ick Shaker kit is composed by the following items A Remote Central Control Unit CCU B Stick Shaker module to be installed onto Captain s control yoke C Optional Stick Shaker module to be installed onto First Officer s control yoke D Universal driver interfacing the Stick Shaker kit to a compatible simulator E USB cable F LAN cable G Cables connecting the Stick Shaker modules to the CCU H CCU Power...

Page 5: ...rt letting to use the Stick Shaker kit in a variety on LAN environments User s selectable COM port when the Stick Shaker kit is connected via USB cable High quality and robust materials all metal built Compatible with any flight simulation software that supports FSUIPC or equivalent interface including X Plane FSX FSX Steam FS9 and Prepar3D Compatible with most add on aircraft including PMDG 737NG...

Page 6: ... it by simply double clicking the icon If needed it can be run also directly from the DVD or USB pen drive supplied in the Stick Shaker kit To perform the initial Stick Shaker hardware configuration Make sure the CCU is powered ON and connected to the computer by either LAN or USB cable Make sure the stick shaker modules are connected to the CCU The hardware setup changes depending if the CCU has ...

Page 7: ...icked My Computer on the desktop or by running the management console directly via devmgmt msc from Windows command line search box start button as follows After the management console has been invoked via either of the methods previously explained all the peripherals installed in the computers are displayed in a tree like style To get a list of installed COM ports just click Ports COM LPT like in...

Page 8: ...ers and no further steps are required Differently before using the Stick Shaker it will be necessary to enter the setup page and input the LAN parameters accordingly as follows Connect the CCU directly to a computer s LAN port avoiding to operate through a switch or router if simpler you may configure the CCU using another computer as the settings will be permanently stored inside the CCU itself n...

Page 9: ...d leave Enable DHCP deactivated enter the IP Address for the Stick Shaker CCU device For example if the LAN where the Stick Shaker will be actually used is based on range 10 0 0 x and 199 is free enter 10 0 0 199 otherwise just enter the IP address suitable for your LAN leave the Subnet Mask at 255 255 255 0 or set it to match your LAN setup leave the HTTP Port at 80 set both Source and Destinatio...

Page 10: ...ton on the side of the LAN port Once the LAN setup of the CCU has been completed the computer s IP address can be restored back to the previous values Now just reconnect the computer to the LAN and connect the CCU to the network port where it will actually operate If all the steps where made correctly the CCU will be seen by your LAN as expected If you would like to make a test supposing that no f...

Page 11: ...u are operating is able to communicate with the CCU Differently a timeout error will be displayed as shown below IMPORTANT Ping command may not work even if the CCU configuration is OK if firewall or other software is blocking such command eventually make sure to disable them before doing such test In case you will contact customer support department to submit issues we will need to know if the co...

Page 12: ...light simulator and make sure that FSUIPC or equivalent interface is started and operating normally Start the flight and select the aircraft that you wish to use with the Stick Shaker Run stickshaker application The first time the application is run error messages indicating that no communication is established are displayed this is normal until the Stick Shaker driver is not properly configured F...

Page 13: ...ng a glass cockpit software or an add on aircraft that use a custom offset just select the relevant option and set such offset and bit please refer to the documentation shipped with the add on to know how the exact offset and bit Click ACTIVATE NOW to test the stick shaker and DEACTIVATE to stop it If communication parameters were changed you must restart the Stick Shaker driver before doing any t...

Page 14: ...a PD Italy 39 049 8657111 Branch Demo Room Via Santa Maria 83 20093 Cologno Monzese MI 39 02 25397214 Broadcast Branch Via Monte Pertica 31 00195 Roma 39 06 37513188 Cap Soc 2 980 000 00 i v CF VAT IT01960110243 C C I A A 196705 Iscritta al Tribunale di Bassano del Grappa N 5618 Reg Soc www professionalshow com ME137437 English ...