Parameter Set
Value
Function
Password
To View
Password
To Edit
Shutdown
Outlet
Temperature
235 °C
A shutdown alarm will be activated if
the air-end discharge temperature
reaches this set value.
Note: Only the over-temperature air-
end(s) will be shut down; the other(s)
will continue to run.
User Factory
Warning Outlet
Temperature
230 °C
A warning will be activated if the air-
end discharge temperature reaches
this set value.
Note: Only the over-temperature air-
end(s) will be flagged.
User Service
Shutdown
Ambient
Temperature
This parameter will
not be displayed if
the ambient
temperature
monitoring function is
disabled.
Provision for a shutdown alarm that
will be activated if the ambient
temperature reaches this set value
and the ambient temperature
monitoring function has been
enabled. Note: The compressor set
does not have this functionality.
Service Factory
Warning
Ambient
Temperature
This parameter will
not be displayed if
the ambient
temperature
monitoring function is
disabled.
Provision for a warning that will be
activated if the ambient temperature
reaches this set value and the
ambient temperature monitoring
function has been enabled. Note: The
compressor set does not have this
functionality.
Service Service
Note:
Compressor operation in ambient temperatures above 30°C will significantly reduce the service life of
the consumable parts and necessitate shorter maintenance intervals. Refer to the Instruction Manual.
2.5
Pressure Menu Screen
The pressure menu is accessed via the system menu. Logging-in with the user password allows full access
to view but limited access to edit the parameters; logging-in with the service password is necessary to edit
most of the set values. The pressure menu screen is shown in Figure 2.5.