6.12 AIR E D/MOTOR REMOVAL
Air end/motor removal and installation
(Note: It is important to have clear access to the air end/motor area)
Lifting devices are necessary for the removal and installation of the air end/motor
A) Turn off compressor.
B) Turn off main power and lock out to avoid accidental start-up.
C) Remove all side access panels.
D) Remove Fan assembly. Fan assembly removal necessary only if the motor is going to
be removed.
E) Remove air filter hose from inlet valve body.
F) Remove power supply to solenoid coil on inlet valve.
G) Remove temperature probe from discharge end of air end (
CAUTIO : This is not a
well type probe, oil may run out of air end).
H) Remove all air and oil line to air end and inlet valve (
CAUTIO : Oil may leak from
oil hoses when removed).
I) Remove 4 bolts from base of inlet valve assembly and set inlet valve assembly aside.
J) Remove belt guard screen.
K) Loosen 4 bolts for belt adjustment inside of belt guard.
L) Loosen belts using adjusting bolts.
M) Remove belts. (
Measure position of pulleys on air end shaft and motor shaft
before removing for proper installation and alignment.)
N) Support air end.
O) Remove 2 bolts from oil by-pass valve inside the belt guard.
P) Remove the 4 bolts used to hold the air end and belt guard assembly to motor.
Q) Remove air end and guard assembly out in one piece.
Installation of the air end
Reverse removal instructions and check belt tension before installing the belt guard screen
For motor removal continue from step (Q)
R) Remove cover from motor junction box.
S) Note wire connections.
T) Remove fan assembly if necessary.
U) Remove wires and conduit connectors from the motor junction box.
V) Remove 4 bolts from motor base studs.
W) Lift and remove motor from cabinet.
To reinstall motor and air end, start with step (W) and reverse procedure.