FIELD SELECTION
PROCEDURES TO CONVERT PTO (POWER TO OPEN) TO PTL (POWER TO LOCK)
Remove the rubber cap to expose the capstan wheel.
Slacken both of the capstan release screws two full revolutions,
DO NOT REMOVE.
Remove the sticker from the cover end opening hole.
The strike is now in the Power to Lock mode.
Tighten the two capstan releasing screws replace the rubber cap.
Replace the sticker after changing over locking function.
Insert the “tool pin” through the cover end opening hole
and push down the solenoid. Hold it in position and at the
same time insert the “tool” thru the cover plate opening
hole and turn the capstan wheel in the direction of the
keeper to the stop.