background image

The armature plate (B) is screw fixed onto and through the Anti-Tamper-Bracket (C), with the countersunk 
hex screw (A).The armature plate must remain flexible to allow surface alignment with the MEM magnet 

The armature plate must remain flexible to allow surface alignment with the MEM magnet 

face

face. The MEM Lock will lose holding force without this floating alignment.

1.  Drill a 12mm diameter clearance hole (timber door) or 12.5mm diameter clearance hole (metal door)      
     through the door at the armature plate center fixing location position.
2.  Screw fix the Anti-Tamper Bracket (C) directly to the face of the door with the self-tapping screws provided.
3.  Install armature plate (B) with countersunk hex screw (A) into and through the Anti-Tamper-Bracket (C). 
     Ensure that the 2 flat washers and 1 rubber washer are in place and tighten the screw into the tapped  
     hole of the Anti-Tamper-Bracket(C). 
     Note:The armature plate, when tightened, must remain flexible and be allowed to float as mentioned above.
4.  Install the dome nut (D) through the clearance hole in the door and tighten onto the Countersunk hex 
     screw (A).

Armature Plate Installation Instructions

Spring

Locking Pin

Countersunk

hex screw (A)

Free-Angle

Rubber

washer

Flat washer

Security top  sleeve nut

Flat washer

Anti-Tamper-Bracket(C)

Armature plate(B)

Tapped hole

dome nut(D)

DOOR

Apply drop of provided threadlocker
glue to the thread of the security top 
sleeve nut  to prevent from becoming
loose.   

Key Screw

NOTE: Make sure to mount  the rubber washer and
            the flat washer for shock absor ption and to
            obtain the holding strenght.      

Installation diagram 

2

12 VOLT JUMPER POSITION

24 VOLT JUMPER POSITION

SPARE

JUMPER

(D)

(B)

(C)

Door

Door Frame

Magnet

(D)

(B)&(C)

Summary of Contents for MEM2400LP

Page 1: ...00LP Mechanical Electro Magnetic Lock operates on either 12 or 24 VDC It is set ex factory on 24VDC and can be changed over to 12V DC by voltage jumper selection see installation diagram When power is applied to the lock and the door is in the closed position the Armature Plate is magnetically attracted to the MEM device and both the DSS LSS switches change status to NC When pressure is applied to...

Page 2: ... C Ensure that the 2 flat washers and 1 rubber washer are in place and tighten the screw into the tapped hole of the Anti Tamper Bracket C Note The armature plate when tightened must remain flexible and be allowed to float as mentioned above 4 Install the dome nut D through the clearance hole in the door and tighten onto the Countersunk hex screw A Armature Plate Installation Instructions Spring L...

Page 3: ...n Using the template provided secure the MEM2400LP MEM Lock firmly on the door frame with the provided screws and have it checked periodically for any possible screw loosening MEM2400LP Output and Indication Status Table Condition Serial number 1 2 3 4 5 Power OFF Door Closed Power OFF Door Open Power On Door Open Power On Door Closed Power On Door Closed Tampered DSS EW1 EW2 LSS Indication on Loc...

Page 4: ... mounting with MEM2400 Anti Tamper Bracket The Glass Door U Bracket is used to clamp on the MEM Lock as well as the Armature Plate to either a frameless glass door or a frameless glass header As mentioned above the adjustable L Bracket has to be ordered separately and can be used on frameless glass headers The product No AMGB24 12 has one unit in the box Frameless glass door and frameless glass fr...

Reviews: