Contacting surfaces of the Mechanical Electro Magnetic Lock and Armature Plate must be kept free of
contaminating materials. Surfaces should be cleaned periodically with a non-abrasive cleaner. Do not
spray the MEM Lock or Armature Plate surface with any lacquer chemicals. This will cause serious
problems with the release of the Armature plate from the Mechanical Electro Magnetic Lock leading to
possible serious safety problems.
Important Safety Precaution
Using the template provided, secure the MEM2400LP MEM Lock firmly on the door frame with the provided
screws and have it checked periodically for any possible screw loosening.
MEM2400LP Output and Indication Status Table
Condition
Serial
number
1
2
3
4
5
Power OFF
Door Closed
Power OFF
Door Open
Power On
Door Open
Power On
Door Closed
Power On
Door Closed &
Tampered
DSS
EW1
EW2
LSS
Indication on Lock
(LP)
Power Off No
LP Indication
Power Off No
LP Indication
Red LP ON
Green LP ON
Green LP ON
Installation dimension
35.0
120.0
164.0
194.0
12
.5
18
.5
Armature Plate & Anti-Tamper
30
.5
Bearing sleeve nut
30.0
5.5
158.0
Light feature
MEM2400LP model (Light Panel)
3
120.0
38.0