8
Function Menu
Main Menu
Function
Function
F1
Scopes & Audio Meters 1
Scopes & Audio Meters
F2
Scopes & Audio Meters 2
Video
F3
Scopes & Audio Meters 3
Audio
F4
Marker
Marker
F5
Measurement (10Bit)
System
Function Display
On
Alarm
OSD
GPI
Color Management
System Status
Support
The Function Menu allows you to assign user selectable functions to any of the 5 function buttons (F1, F2, F3, F4, & F5)
on the monitor keypad. Many monitor features listed as assignable options in the function menu are also selectable via the
embedded menus and are present simply to provide an option for faster, single button press access to the desired function.
Other features listed require a function key for activation, but may have associated customizable settings that can be found
in other menus.
Assigning Function Keys
To assign a function to a function key highlight one of the 5 Function lines and press ENTER. A list of assignable functions
will appear. Select the desired function with the UP and DOWN buttons and press ENTER to assign that function to the
corresponding function key. The Function Display option at the bottom of the Function Menu gives you the option to have
a temporary confirmation window appear on screen after a function key is pressed that will identify the function that was
turned on or off.
Scopes & Audio Meters 1, 2, 3
These functions toggle on/off a Scopes & Audio Meters profile. Three profile slots are available from the Scopes & Audio
Meters Menu and each profile can be set to a specific function key allowing you to instantly toggle between various types of
Scope and/or Audio Level Meter configurations. Please note that if you have set both Scopes Windows to the Off position in
the Scopes & Audio Meters menu nothing will appear on screen when you toggle this function (see
section of this manual for more details).
Cross Hatch
The Cross Hatch function toggles on/off the onscreen display of a graphical cross hatch overlay.
Marker 1, 2, 3
These functions activate the onscreen display of the preset Area, Safety, Custom Graticules, or Active Boundary Markers as
set in the Marker Profiles. Marker Profiles can be customized via the Marker Menu. By utilizing this function you can toggle
on/off your selected markers with a single function key (see
section of this manual for more details).
Overscan
The Overscan function can work with 1:1 Pixel mapping mode on or off. With 1:1 Pixel to Pixel mapping mode turned off
the Overscanned image is scaled full screen. With 1:1 Pixel to Pixel mapping mode turned on the image remains unscaled,
but the area lying outside of the active scan area is blacked out. This area represents the same area not visible with Pixel
to Pixel mode off.
WARNING: Changing a function button
assignment does NOT automatically
turn an active function off. Make sure to
disable unwanted active functions before
changing function button assignments.
NOTE: Many features (Waveform,
Vector Scope, Audio Level
Meters, etc.) require a function
key in order to operate. Some
menus (such as the Scopes &
Audio Meters Menu) only set
your display preferences while a
corresponding function key must
be assigned to turn the feature
on and off. If you are having
trouble with a monitor feature
make sure you have assigned
the proper function key and any
corresponding menu settings.