Carefully read all instructions prior to use. Observe all contraindications, warnings and 
precautions noted in these directions. Failure to do so may result in patient complications.

Device Description

The 60Ghz WUH4000 transmitter wirelessly transmits high quality audio and video to a paired 
WUH4000 receiver in a typical operating room. The transmitter is designed to be connected to a 
video source (such as an endoscopic camera) with the receiver connected to a video monitor.

Two WUH4000 transmitter/receiver systems operating at diff erent frequencies within the 60Ghz 
band can be used simultaneously within the same room. 

The WUH4000 is designed to be unaff ected by cell phones, RFID, wireless 802.11 b/g/n. The 
60Ghz operating frequency cannot pass through walls and will work within a 10m radius. 256-bit 
AES encryption ensures that no other devices can speak with the WUH4000. 

The WUH4000 transmitter dimensions are:
75.8 mm (2.98 in.) high x 140 mm (5.51 in.) wide x 98.25 mm (3.87 in.) deep.
Weight is approximately .57 kg (1.25 lbs). 

The WUH4000 receiver dimensions are: 
75.8 mm (2.98 in.) high x 55 mm (2.17 in.) wide x 98.25 mm (3.87 in.) deep.
Weight is approximately .23 kg (.5 lbs). 

Both components are mains powered (100 – 240 V).

The WUH4000 wireless device is a non-sterile reusable device not intended for use in the sterile fi eld. 

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

 

Part Number 

Transmitters 

Receivers 

Designed for FHD 

Designed for 4K

 FHD-1TX-1RX 

 FHD-1TX-2RX 

 WUH4000 

 

 WUH4000-D 

 

AV Source

Transmitter (TX)

Receiver (RX)

Destination

Product Description / Intended Use

Summary of Contents for FHD-1TX-1RX

Page 1: ...nstructions for Use Model WUH4000 Part Numbers FHD 1TX 1RX FHD 1TX 2RX WUH4000 WUH4000 D Model WUH4060 Before connecting operating or adjusting this product please read this instruction booklet carefully and completely English ...

Page 2: ...r Use 23 25 General Specification 26 27 Video Resolution Timing 28 Appendix 29 30 WUH4060 Maintenance of Quality Service 31 32 Package Contents 33 Installation 34 35 Panel Interface 36 Directions for Use 37 38 General Specification 40 41 Video Resolution Timing 42 The specifications and information in this document are subject to change without notice Instructions for Use for this product are also...

Page 3: ...D wireless 802 11 b g n The 60Ghz operating frequency cannot pass through walls and will work within a 10m radius 256 bit AES encryption ensures that no other devices can speak with the WUH4000 The WUH4000 transmitter dimensions are 75 8 mm 2 98 in high x 140 mm 5 51 in wide x 98 25 mm 3 87 in deep Weight is approximately 57 kg 1 25 lbs The WUH4000 receiver dimensions are 75 8 mm 2 98 in high x 55...

Page 4: ... with other wireless devices The system is designed to link within the same room and will work on the same floor within a 30 meter radius 256 bit AES encryption ensures that no other devices can speak with the WUH4060 The WUH4060 transmitter dimensions are 132 mm 5 20 in high x 91 mm 3 58 in wide x 27 mm 1 06 in deep Weight is approximately 360g 79 lbs The WUH4060 receiver dimensions are 112 mm 4 ...

Page 5: ...ion Importer Entity UK Conformity Assessed Indicates proof of conformity to EU 2017 745 Medical Devices Regulation and applicable standards Medical Equipment is in accordance with ANSI AAMI ES60601 1 A1 2012 C1 2009 R 2012 and A2 2010 R 2012 CSA CAN CSA C22 2 NO 60601 1 14 Medical electrical equipment Part 1 General requirements for basic safety and essential performance Tested to comply with FCC ...

Page 6: ...th the requirements of IEC 60601 1 1 If in doubt contact a qualified technician or your local representative Contraindications This device is not intended to be used in the vicinity of diathermy equipment This device is not intended to be used in the sterile field Intended User Wireless Systems are intended to be used by trained video system professionals Warning Before connecting the AC power cor...

Page 7: ...ty guidelines have yet been established Controversy exists as to whether these effects are harmful to humans Exposure to RF radiation may be reduced by limiting your use of this device and keeping away from the head and body Repair Unplug the apparatus from its power source and refer servicing to qualified personnel under the following conditions If the power cord or plug is damaged or frayed If l...

Page 8: ...connect any other wires or accessories which don t comply with this system to this system An improper wire may cause electric shock or equipment damage Insert wire connections firmly so that they do not come loose A bad connection may cause a fault Do not stack and locate close to other equipment To prevent fire or shock hazards do not expose this unit to rain or moisture Do not use this unit s po...

Page 9: ...lies to the above standards only when used with the supplied medical grade power supply Wireless Imaging System Power Supply WUH4000 Adapter Technology ATM036T P050 WUH4060 CUI INC SDM36 12 U P5 Caution Make sure the power cord is the correct type that is required in your area This system has a universal power supply that allows operation in either 100 120V AC or 200 240V AC voltage areas no user ...

Page 10: ...r help NOTICES TO USER This device complies with the requirements of FCC CFR 47 Part 15 Subpart B Operation is sub ject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation However if used incorrectly RF interference could hamper its operation or the operation o...

Page 11: ...nce level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or cera mic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast tran sient burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input out put lines 2 kV for power supply lin...

Page 12: ...RF transmitters as determined by an elec tromagnetic site survey a Should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note 1 UT is the A C mains voltage prior to application of the test level Note 2 At 80MHz and 800 MHz the higher frequency range applies Note 3 These guidelines may not apply in all...

Page 13: ...er W of transmitter Separation distance according to frequency of transmitter m 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2 5GHz 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 70 3 70 7 37 100 11 70 11 70 23 30 For transmitters rated at a maximum output power not listed above the recommended separation dis tance d in meters m can be estimated using the equation applicable to the freq...

Page 14: ... in the vicinity of equipment marked with the following symbol Note 1 These guidelines may not apply in all situations Electromagnetic propagation is affected by ab sorption and reflection from structures objects and people Note 2 It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to assure that they meet the minimum specification Fi...

Page 15: ...complies with Canadian ICES 003 and RSS 210 Cet appareil nu mérique de la classe B conforme á la norme NMB 003 et RSS 210 du Canada Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device EU Declaration of Conformity DoC Hereby declares that t...

Page 16: ...f the transmitter Using its unique mating procedure the WUH4000 transmitter is constructed to work only with the WUH4000 authenticated receivers It s HDCP protocol not only blocks hackers from high jacking or altering a signal but it also stops other WUH4000 Transmitters Receivers from breaking into the communication between linked Transmitter and Receiver If more than one WUH4000 wireless systems...

Page 17: ...wing The TX and RX are facing each other The TX and RX are no more than 10 meters apart The TX and RX are between 6 10 ft above the floor The TX and RX are not in a confined location Noninterference Distances The following minimum distances have been tested to demonstrate noninterference between the listed devices and the WUH4000 If the WUH4000 is thought to be causing or receiving inter ference w...

Page 18: ...mount bracket 2 8 HDMI 1 4 to HDMI 1 4 cable 1 5 feet 1 9 HDMI to DVI cable 1 5 meter 2 10 Video splitter adapter optional if required 1 11 Micro USB cable for power from wireless receiver to splitter adapter 1 5 feet 1 12 Mounting screw packet 1 Option is available for one of the two cables to be 3 meter Verify that all components for the respective package are accounted for Inspect each componen...

Page 19: ...wer adaptor 2 5 Power cord 2 6 User guide 1 7 Monitor VESA mount bracket 2 8 HDMI 2 0 to HDMI 2 0 cable 2 meter 2 9 Mounting screw packet 1 Verify that all components for the respective package are accounted for Inspect each component to verify that none have been tampered with in any way Package Contents Part No WUH4000 Model WUH4000 ...

Page 20: ... RX unit example D Find a suitable power source for the receiver The transmitter and receiver units can stand alone on a flat surface or use a bracket to mount onto other objects such as a display monitor It is recommended to verify that the wireless system is operating properly before mounting the TX or RX units permanently For best installation results The TX and RX should face each other The TX...

Page 21: ...x Rx A properly operating wireless system TX source destination RX Example of the supplied VESA mount bracket attached to the back of a display monitor The WUH4000 RX or TX is con nected to the VESA mount bracket ...

Page 22: ...unit Power LED Green color Shows if the TX and RX units have power or not SET button Will reactivate the WUH4000 system if in sleep mode Power input Supplies power to the TX or RX units Factory service Used for authorized manufacturer diagnostics or upgrades Panel Interface WUH4000 Transmitter Receiver Power input Power input Link LED Link LED Link LED Factory service Factory service or video adap...

Page 23: ...ignal HD display monitor or similar destination Wireless signal connection if required Power adapter Power adapter Video adapter Video Adapter Most HD display monitors using a DVI signal can be connected directly to the WUH4000 receiver RX unit However if WUH4000 is unable to successfully transmit video from the TX to the RX then the video adapter that is supplied with WUH4000 may be required to e...

Page 24: ...ypical Configuration Directions for Use Part No WUH4000 WUH4000 D Model WUH4000 4K UHD source signal HDMI input to transmitter HDMI output from receiver 4K UHD display monitor or similar destination Wireless signal connection Power adapter Power adapter ...

Page 25: ... destination Briefly pressing the SET button will also exit sleep mode SET button Briefly press the SET button to exit sleep mode The SET button is also used for advanced RX TX unit pairing and factory reset procedures Contact FSN Medical Technologies for detailed information NOTE All WUH4000 TX and RX units sold together are programmed at the factory and should connect automatically If not purcha...

Page 26: ...mpliance HDCP 2 2 Resolution FHD 480i 480p 60Hz 576i 576p 50Hz 720p 50 60Hz 1080i 50 60Hz 1080p 24 30 50 60Hz UHD 4K 3840 x 2160 24 30 60Hz input 4K 3840 x 2160 24 30Hz output Audio interface Audio output Up to 7 1 channels high bit rate Audio format LPCM channels 2 6 8 S PDIF channels 6 8 Control status indicator Wireless link set TX 2 x SET buttons RX 1 x SET button TX 2 x link LED amber RX 1 x ...

Page 27: ...1 CE RED EN 301 489 1 EN 62311 EN 60950 1 EN 302 567 CE UL EMC EN 60601 1 IEC EN 60601 1 2 Japan TELEC Korea Compliance KCC VCCI Compliance VCCI Green RoHS Specification continued WUH4000 Recycling WEEE Directive 2012 19 EU Follow local governing ordinances and recycling plans regarding the recycling or disposal of this requirement Cleaning Instructions Follow your hospital protocol for the handli...

Page 28: ... 2 2 8 bits 480p 60Hz RGB YCbCr YCbCr 4 4 4 8 10 12 bits 4 4 4 8 10 12 bits 4 2 2 8 bits 576i 50Hz RGB YCbCr YCbCr 4 4 4 8 10 12 bits 4 4 4 8 10 12 bits 4 2 2 8 bits 576p 50Hz RGB YCbCr YCbCr 4 4 4 8 10 12 bits 4 4 4 8 10 12 bits 4 2 2 8 bits 720p 50Hz 60Hz RGB YCbCr YCbCr 4 4 4 8 10 12 bits 4 4 4 8 10 12 bits 4 2 2 8 bits 1080i 50Hz 60Hz RGB YCbCr YCbCr 4 4 4 8 10 12 bits 4 4 4 8 10 12 bits 4 2 2...

Page 29: ...o verify that none have been tampered with in any way Item Description Quantity 1 Wireless transmitter TX unit 1 2 Wireless receiver RX unit 2 3 Power adapter 3 4 Power cord 3 5 User guide 1 6 Monitor VESA mount bracket 3 7 HDMI 1 4 to HDMI 1 4 cable 1 5 feet 2 8 HDMI to DVI cable 1 5 meter 3 9 Video splitter adapter optional if required 2 10 Micro USB cable for power from wireless receiver to spl...

Page 30: ...in this guide Verify that all components for the respective package are accounted for Inspect each component to verify that none have been tampered with in any way Item Description Quantity 1 Wireless transmitter TX unit 1 2 Wireless receiver RX unit 2 3 Power adaptor 3 4 Power cord 3 5 User guide 1 6 Monitor VESA mount bracket 3 7 HDMI 2 0 to HDMI 2 0 cable 2 meter 3 8 Mounting screw packet 1 APP...

Page 31: ...5 feet As a result of these design considerations it is not possible for one WUH4060 System to interfere with another WUH4060 System Design Considerations Interference from other Devices The WUH4060 is validated to be compatible with other devices that are commonly found in an operating environment in accordance with IEC 60601 1 2 In that testing the WUH4060 needed to maintain the following Essent...

Page 32: ...d RX are not in a confined location Noninterference Distances If the WUH4060 is thought to be causing or receiving interference with any other devices then move the devices away from each other The WUH4060 is not intended to be used in the vicinity of diathermy equipment If diather my equipment is operated around the WUH4060 and interference is suspected turn off the WUH4060 Transmitter and Receiv...

Page 33: ...ter TX unit 1 2 Wireless receiver RX unit 1 3 Power adapter 2 4 Power cord 2 5 WUH4060 VESA mount bracket 2 6 HDMI 2 0 to HDMI 2 0 cable 2 meter 2 7 Mounting screw packet 2 Verify that all components are accounted for Inspect each component to verify that none have been tampered with in any way ...

Page 34: ...ion of the WUH4060 receiver RX unit example D Find a suitable power source for the receiver The transmitter and receiver units can stand alone on a flat surface or use a bracket to mount onto other objects such as a display monitor It is recommended to verify that the wireless system is operating properly before mounting the TX or RX units permanently For best installation results The TX and RX sh...

Page 35: ...21 A properly operating wireless system TX source destination RX Example of the supplied VESA mount bracket attached to the back of a display monitor The WUH4060 RX or TX is connected to the VESA mount bracket ...

Page 36: ...RX video signal is connected Power switch LED Off power is off On power is on HDMI in TX Video source input 12G in TX Video source input Loop 12G out TX Video loop out HDMI out RX Video output to destination 12G out A RX Video output to destination 12G out B RX Video output to destination DC power in 12V 5A power input USB port Firmware upgrade Panel Interface WUH4060 Transmitter Receiver OLED dis...

Page 37: ...ation Directions for Use WUH4060 4K UHD source signal input to transmitter Output from receiver to destination HDMI or 12G SDI 4K UHD display monitor or similar destination Wireless signal connection Power adapter Power adapter ...

Page 38: ...for Menu Lock Unlock status If locked push and hold the joystick button left toward antennas to unlock Use this same procedure to lock the OLED display after all steps have been completed 3 Enter the OLED menu by pushing the joystick button right away from antennas 4 Search for 3D Mode by navigating with the joystick button up down to select 3D the desired 3D mode Auto Side x Side or Line Alternat...

Page 39: ...ing right on the joystick twice Select PROCEED TO UNPAIR A message UNPAIRING PLEASE WAIT is briefly displayed 6 Next select the PAIR mode by pushing right on the joystick once to start pairing A message PAIRING SEARCHING FOR TX is displayed 7 Prepare Transmitter TX Confirm that the power on 8 Check the TX OLED display for the Lock Unlock menu If Locked push and hold the joystick left for 5 seconds...

Page 40: ... only YUV 4 2 0 8 bit RGB YUV 4 4 4 10 bit All formats except 4K50p to 60p RGB YUV 4 4 4 8 bit 12G YUV 4 2 2 10 bit YUV 4 2 2 12 bit All formats except 4K50 to 60p YUV RGB 4 4 4 10 bit All formats except 4K50p to 60p Audio interface Audio channel 2 channels Audio format PCM 48Khz 24bit Maintenance FW upgrade Micro USB 2 0 Control Status indicator 3 x LED indicators 1x Power On Off indicator 1x Wir...

Page 41: ...AMN42012 CE EMC EN 55011 209 A1 2010 EN 60601 1 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 301 489 1 v2 1 1 EN 301 893 v2 1 1 EN 62311 CE RED EN 300 328 v2 1 1 VCCI VCCI CISPR 32 2016 Specification continued WUH4060 Recycling WEEE Directive 2012 19 EU Follow local governing ordinances and recycling plans regarding the recycling or disposal of this requirement Cleaning Instructions Follow your h...

Page 42: ... 2 2 Y Y 3840x2160 UHD 60Hz 59 94Hz 50Hz YUV 12 bit 4 2 2 Y 1080p HD 60Hz 59 94Hz 50Hz 30Hz 29 97Hz 25Hz 24Hz 23Hz RGB 8 bit 4 4 4 Y 1080p HD YUV 8 bit 4 4 4 Y Y 1080p HD YUV 8 bit 4 2 2 Y 1080p HD YUV 10 bit 4 2 2 Y Y 1080p HD YUV 12 bit 4 2 2 Y 1080i HD 60Hz 59 94Hz 50Hz RGB 8 10 bit 4 4 4 Y 1080i HD 60Hz 59 94Hz 50Hz YUV 8 10 bit 4 4 4 Y 1080i HD 60Hz 59 94Hz 50Hz YUV 8 10 bit 4 2 2 Y 720p HD 6...

Page 43: ...43 8 2021 ...

Page 44: ... UK Ltd 1 Wolsey Road East Molesey Surrey KT8 9EL United Kingdom Tel 44 0 208 546 1047 FORESEESON KOREA 404B Pangyoinnovalley B 253 Pangyo ro Bundang gu Seongnam si Gyeonggi do Korea 463 400 Tel 82 31 8018 0780 Fax 82 31 8018 0786 FORESEESON Shanghai Medical Equipment Co Ltd Room 307 3F No 56 461 Hongcao Road Caohejing Development District Xuhui Shanghai 200233 Tel 86 21 6113 4188 FORESEESON CUSTO...