background image

- 8 - 

 

3.2.2 PV Charging 

To perform system charging via PV power source, the following steps are to be followed.

 

Step 1: Connect PV charging cable adaptor to 

PV INLET

 first, as illustrated in Figure 3. 

Step 2: Connect MC4 connectors from the cable adaptor to MC4 connectors from PV panels. 

Use Y Type MC4 connectors (not provided) for multiple PV panel branches. 

 

 

Figure 3. PV charging 

 

Step 3: Turn on the system by pressing 

MSW

 

When EMERGY 1000 is charging by PV

 

power, 

CHARGING INDICATOR

 will light up 

CHARGING 

INDICATOR

 will turn off automatically when charging is terminated. 

EMERGY 1000 would take about 3 hours for a full charger cycle (from empty to full) when PV 

power is greater than 650Wp and it is optimal solar radiation. 

 

 

Failure to connect the cable adaptor first may cause unexpected electrical 

shock from exposed connector pins in the adaptor before follow-up step. 

 

Proper PV configuration should be used to ensure suitable input voltage 

range for PV charger of EMERGY 1000 (refer to product specifications). 

Excessive voltage level (>200V) may result in damage to PV charger. 

 

 

 

 

Summary of Contents for EMERGY 1000

Page 1: ... EMERGY 1000 User Manual Please read this User Manual first before Operating the System ...

Page 2: ...and Functions 3 2 2 Gauge Charging Indicators and Alarm 4 3 SYSTEM OPERATIONS 7 3 1 Turning On Off System 7 3 2 Charging System 7 3 3 System Outputs 9 3 4 Operating Modes 9 3 5 Physical Positioning 10 3 6 Apparatus Equipment Appliances 10 4 TRANSPORTATION 12 5 STORAGE 13 6 IN CASE OF EMERGENCY 14 7 MAINTENANCE 14 8 WARRANTY 15 ...

Page 3: ...ts reserved Reproduction adaptation or translation of this document without prior written permission is prohibited except as allowed under the copyright laws 1 2 Symbol Used Symbols Meaning Description DANGER Beware dangerous voltage WARNING It calls attention to a procedure practice or the like which if not correctly performed or adhered to could result in personal injury CAUTION It calls attenti...

Page 4: ...agement System AC charger Photovoltaic PV charger DC to AC inverter System Control into the compact portable suitcase 2 1 Appearance and Functions Figure 1 illustrates the appearance and key external parts in EMERGY 1000 The functions of each key parts are highlighted in Table 1 Figure 1 a Top View Figure 1 b Rear View ...

Page 5: ...EM INDICATOR System status indication USB power outlet is synched with system power Light up when power is present 9 AC OUT INDICATOR AC output power indication Light up when power is present 10 MODE INDICATOR Indicate operating mode Light up for On Line Mode Turn off for Standby Mode 11 LIFT HANDLE For Lifting EMERGY 1000 12 PULL HANDLE For pulling pushing the system while on wheels Not for lifti...

Page 6: ...al battery capacity as illustrated in Table 2 Table 2 Gauge Indicators Status Meaning 5 LEDs On GGWOR SOC 80 4 LEDs On GGOR SOC between 60 80 3 LEDs On GOR SOC between 40 60 2 LEDs On OR SOC between 20 40 1 LED On R SOC between 10 20 Charge Soon 1 LED blinking R SOC between 0 10 Charge Immediately All LEDs Off MSW is off or battery fully drained F 3 4 H 1 4 E F 3 4 H 1 4 E F 3 4 H 1 4 E F 3 4 H 1 ...

Page 7: ...rrent is less than 2A 3 When closing to fully charged it is normal whether CHARGER INDICTOR is blinking or not Off Five GAUGE INDICATORs are all on and CHARGING INDICATOR is off if the system is fully charged 2 2 3 Alarm When the remaining battery capacity drops below 15 an alarm sound a periodical short buzz will be initiated to inform user that the battery may run out of energies soon It should ...

Page 8: ...l toggle the system status 3 2 Charging System 3 2 1 AC Charging To perform system charging via AC power source the following steps are to be followed Step 1 Turn on the system by pressing MSW Step 2 Connect power cord IEC320 type to AC INLET as illustrated in Figure 2 Figure 2 AC charging When EMERGY 1000 is charging CHARGING INDICATOR will light up CHARGING INDICATOR will turn off automatically ...

Page 9: ...s charging by PV power CHARGING INDICATOR will light up CHARGING INDICATOR will turn off automatically when charging is terminated EMERGY 1000 would take about 3 hours for a full charger cycle from empty to full when PV power is greater than 650Wp and it is optimal solar radiation Failure to connect the cable adaptor first may cause unexpected electrical shock from exposed connector pins in the ad...

Page 10: ...is turned on thru pressing MSW DC output is also turned on When the system is turned off DC output is also turned off A total of 2A current is available for the two USB outlets 3 4 Operating Modes The default operating mode for EMERGY 1000 is Standby mode To toggle between Standby mode and On Line mode lightly press MODE button MODE INDICATOR will turn on under On Line mode and turn off under Stan...

Page 11: ...d apparatus equipment appliances certain loads that require heavy surge current may not operate properly A list of apparatus equipment appliances that are compatible or incompatible with EMERGY 1000 are shown Table 4 Table 4 Loads Supports Operate Properly Not Operate Properly 1 Consumer electronics Mobile phones tablets NBs PCs monitors projectors desk top printer copier shredder etc 2 Household ...

Page 12: ...t 30W 27 0 hours Fluorescent Lamp 36W 22 5 hours Home Appliance Radio 10W 81 0 hours Electric Fan 66W 12 3 hours Refrigerator 130W 6 2 hours 42 LCD TV 200W 4 1 hours Sound System 200W 4 1 hours Toasters 600W 1 4 hours Electric Pot 800W 1 0 hours Heater 1 000W 0 8 hours Induction Cooker 1 200W 0 7 hours 3C Smart Phone 2W 405 0 times Tablet 20W 40 5 times Notebook Computer 40W 20 3 hours Projector 2...

Page 13: ...arrying EMERGY 1000 in rougher outdoor terrains The correct ways for moving and carrying EMERGY 1000 are illustrated in Figure 5 Figure 5 Moving and Lifting EMERGY 1000 Locking mechanisms are provided in the two front wheels of EMERGY 1000 Figure 6 illustrates how to engage or dis engage the locking mechanism Figure 6 Wheel Locking Mechanism Front wheels Rear wheels ...

Page 14: ...ystem s availability In extreme case the battery may be over discharged rendering expensive replacement of the battery The following practices should be exercised when storing EMERGY 1000 1 Charge EMERGY 1000 to 50 70 capacity For short term storage while preparing for usage charge the system to full capacity 2 Turn off MSW All panel lights should be off 3 Place the system in solid footing to avoi...

Page 15: ... batteries to avoid possible over discharge during storage especially after usage The appearance and surface can be cleaned with a damped cloth with water DO NOT attempt to repair EMERGY 1000 yourself All units should be returned to authorized vendor or repair center for repair Unauthorized opening of the system case will void product warranty and may expose the user to dangerous high voltage DO N...

Page 16: ...iscretion whether to repair or to replace system assembly part s found to be defective Transportation to the service center or the factory is the responsibility of the purchaser This warranty is void for products repaired or altered by the customer or any unauthorized person or entity This warranty also does not cover damages caused by improper use accidents and natural disasters ...

Page 17: ... Purchase Purchase From Name Address City State Zip Phone E mail Please keep this warranty card for future reference Contact Information FSP USA Add 14284 Albers Way Chino California Tel 909 606 0960 E mail info fspgroupusa com Web www fspgroupusa com ...

Page 18: ... Contact Information FSP USA Add 14284 Albers Way Chino California Tel 909 606 0960 E mail info fspgroupusa com Web www fspgroupusa com ...

Reviews: