Trouble Shooting
Use the table below to solve minor problems.
Problem
Possible Cause
Solutions
No LED display on the
front panel.
Low battery.
Charge the UPS at least 6 hours.
Battery fault.
Replace the battery with the same
type of battery.
The UPS is not turned on.
Press the power switch again to turn
on the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overloaded.
Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
When power fails,
back-up time is
shorten.
The UPS is overloaded.
Remove some critical load.
Battery voltage is too low.
Charge the UPS at least 6 hours.
Battery defect. It might be
due to high temperature
operation environment, or
improper operation to battery.
Replace the battery with the same
type of battery.
The mains is normal
but LED is flashing.
Power cord is loose.
Reconnect the power cord securely.
6.
Specifications
Model
FP 400
FP 600
FP 800
CAPACITY
400 VA / 240 W
600 VA / 360 W
800 VA /480 W
INPUT
Voltage
220/230/240 VAC
Voltage Range
162-290 VAC
OUTPUT
Voltage Regulation
+/-10%
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
BATTERY
Type & Number
12 V/4.5 AH x 1
12 V/7 AH x 1
12 V/9 AH x 1
Charging Time
4-6 hours recover to 90% capacity
PHYSICAL
Dimension (DxWxH)
279 x 101 x 142 mm
Net Weight (kgs)
3.55
4.2
4.9
Environment
Humidity
0-90 % RH @ 0-40° C (non-condensing)
Noise Level
Less than 40 dB