Trouble Shooting 

Use the table below to solve minor problems. 

Problem 

Possible Cause 

Solutions 

No LED display on the 
front panel. 

Low battery. 

Charge the UPS at least 6 hours. 

Battery fault. 

Replace the battery with the same 
type of battery. 

The UPS is not turned on. 

Press the power switch again to turn 
on the UPS. 

Alarm continuously 
sounds when the 
mains is normal. 

The UPS is overloaded. 

Remove some loads first. Before 
reconnecting equipment, please 
verify that the load matches the UPS 
capability specified in the specs. 

When power fails, 
back-up time is 
shorten. 

The UPS is overloaded. 

Remove some critical load. 

Battery voltage is too low. 

Charge the UPS at least 6 hours. 

Battery defect. It might be 
due to high temperature 
operation environment, or 
improper operation to battery. 

Replace the battery with the same 
type of battery. 

The mains is normal 
but LED is flashing. 

Power cord is loose. 

Reconnect the power cord securely. 

 

6.

 

Specifications 

Model 

FP 400 

FP 600 

FP 800 

CAPACITY 

400 VA / 240 W 

600 VA / 360 W 

800 VA /480 W 

INPUT 

Voltage 

220/230/240 VAC 

Voltage Range 

162-290 VAC 

OUTPUT 

Voltage Regulation 

+/-10% 

Transfer Time 

Typical 2-6 ms 

Waveform 

Simulated Sine Wave 

BATTERY 

Type & Number 

12 V/4.5 AH x 1 

12 V/7 AH x 1 

12 V/9 AH x 1 

Charging Time 

4-6 hours recover to 90% capacity 

PHYSICAL 

Dimension (DxWxH) 

279 x 101 x 142 mm 

Net Weight (kgs) 

3.55 

4.2 

4.9 

Environment 

Humidity 

0-90 % RH @ 0-40° C (non-condensing) 

Noise Level 

Less than 40 dB 

 

Summary of Contents for FP 400

Page 1: ...it EN Quick Guide 2 Product Overview Front View Power Switch UPS status LED AC Mode green lighting Battery Mode green flashing Back View A Output receptacles B AC input Options C Circuit breaker Fuse D USB port E Modem phone or Network surge protection Line Interactive UPS Quick Guide V 2 0 ...

Page 2: ...ons Connect to Utility and Charging Plug in the AC input cord to the wall outlet For the best results we suggest to charge the battery for at least 4 hours before initial use The unit charges its battery while connecting to the mains 4 hours Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit then devices connected to t...

Page 3: ...ng is a must during UPS installation in order to reduce leakage current below 3 5mA ATTENTION Even when the UPS is disconnected from the mains there may still be hazardous voltage from the battery The battery should therefore be disconnected at the plus and minus terminals of the battery before maintenance or service work inside the UPS is performed CAUTION Servicing of batteries should be perform...

Page 4: ...d Battery voltage is too low Charge the UPS at least 6 hours Battery defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery The mains is normal but LED is flashing Power cord is loose Reconnect the power cord securely 6 Specifications Model FP 400 FP 600 FP 800 CAPACITY 400 VA 240 W 600 VA 360 W 800 VA 480...

Page 5: ...5 ...

Reviews: