background image

REGULATORY COMPLIANCE

FSR'S ELECTRONIC PRODUCTS have been tested for compliance with: FCC Class A and CE The 

Power Adapter has been tested for compliance with: UL, CSA and CE.

WARRANTY POLICY

This product is warranted against failures due to defective parts or faulty workmanship for a period of 

one year after delivery to the original owner. During this period, FSR will make any necessary repairs 

or replace the unit without charge for parts or labor. Shipping charges to the factory or repair station 

must be prepaid by the owner, return-shipping charges, via UPS / FedEx ground, will be paid by FSR.

This warranty applies only to the original owner and is not transferable. In addition, it does not apply 

to repairs done by other than the FSR factory or Authorized Repair Stations.

This warranty shall be cancelable by FSR at its sole discretion if the unit has been 

subjected to physical abuse or has been modified in any way without written authorization from FSR. 

FSR’s liability under this warranty is limited to repair or replacement of the defective unit.

FSR will not be responsible for incidental or consequential damages resulting from the use or misuse 

of its products. Some states do not allow the exclusion of incidental or consequential damages, so the 

above limitations may not apply to you. This warranty gives you specific legal rights, and you may 

also have other rights which vary from state to state.

Warranty claims should be accompanied by a copy of the original purchase invoice 

showing the purchase date (if a Warranty Registration Card was mailed in at the time of purchase, this 

is not necessary). Before returning any equipment for repair, please read the important information 

on service below.

SERVICE

Before returning any equipment for repair, please be sure that it is adequately packed and cushioned 

against damage in shipment, and that it is insured. We suggest that you save the original packaging and 

use it to ship the product for servicing. Also, please enclose a note giving your name, address, phone 

number and a description of the problem.

NOTE: All equipment being returned for repair must have a Return Authorization (RMA) Number. 

To get a RMA Number, please call:

FSR Service Department (973-785-4347). 

Please display your RMA Number prominently on the front of all packages.

Contact Information:

FSR Inc.

244 Bergen Boulevard, 

Woodland Park, NJ  07424 

Tel: (973) 785-4347 · Fax: (973) 785-4207

E-Mail: sales@fsrinc.com · Web: 

http://www.fsrinc.com

Summary of Contents for IPS-A223S Series

Page 1: ...IPS A223S IPS A511S SERIES UNBALANCED STEREO AUDIO TO BALANCED OUTPUT IPS INSERTS OPERATING GUIDE LIT1262C 43938 ...

Page 2: ...ndy Do Not Remove Covers or Panels There are no user serviceable parts within the unit Power Source This product is intended to operate from the specified wall plug in power supply Do not use any other power source Grounding the Product This product is grounded through the grounding conductor of the power cord To avoid electrical shock plug the power cord into a properly wired receptacle before co...

Page 3: ...un The balanced stereo output assures immunity to noise and ground loop interference FEATURES Indicator LED for power Balanced Stereo Output Buffered Outputs Eliminates ground loops and noise APPLICATIONS Boardrooms Houses of Worship Control Rooms Classrooms Staging and Rental ACCESSORIES A full selection of FSR IPS mounting plates Wall mount power supply included A hugh selection of FSR cables an...

Page 4: ...sulation from the leads to avoid shorting of neighboring screw terminals Screw the terminals down tightly Do not use excessive force while tightening the terminal screws Always check for cable clearance while mounting to avoid pinched cables and shorting Use the supplied screws to mount the interface to the IPS wall plate or rack frame There are tapped holes on the mount ing plate to accept the su...

Page 5: ...LD IPS A223S W PATERSON NJ 973 785 4347 R R GND L L GND 12V SOURCE SIGNAL FLOW OUTPUT COMMON INSTALL JUMPER IPS A223S W PATERSON NJ 973 785 4347 R R GND L L GND 12V SOURCE SIGNAL FLOW OUTPUT TO A MONO UNBALANCED PREAMP INPUT TO A MONO BALANCED PREAMP INPUT SHIELD OPTIONAL JUMPER INSTALL JUMPER IPS A223S IPS A511S AUDIO OUTPUT CONNECTOR WIRING IPS A223S SHOWN BELOW FSR POWER SUPPLY IT PS1 INCLUDED ...

Page 6: ... female jacks Impedance 10 kΩ unbalanced AC coupled Nominal level 0 dBm 0 775 V RMS Maximum level 20 dBm 7 75 V RMS AUDIO OUTPUT Number Signal type One stereo balanced unbalanced Connector Captive screw connector 7 position Impedance 50 Ω Maximum level 26 dBm balanced into 600 Ω 20 dBm unbalanced into 600 Ω POWER Input requirements 12VDC 70mA with full signal 20mA quiescent Power supply FSR IT PS1...

Page 7: ...es resulting from the use or misuse of its products Some states do not allow the exclusion of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date if a ...