User’s manual · TFF 310 CI
- 16 - TFF 310 CI version_en_2.0 FTE maximal
-
Network Option:
This option allows adjusting the identification parameters of multiplex.
-Network name: Associated name to the network.
- TSID: Identification value of Transport Stream. Give a different value of TSID
for each output multiplex configured is recommended.
- NID: Identification value of the network.
- ONID: Original identification value of the network.
- Tables: This option allows modifying the value of the following information
DVB service tables:
-
NIT
-
SDT
-
PAT
2. System
In “System” option the information concerning the regenerator is given.
- SW version info: It allows you to visualize the basic information of the module:
model, firmware version, etc.
- Date / Time: Setting of the date and time of transmodulator. It is appropriate
to maintain these parameters set in order to have the registration of errors
linked to the current time and date.
- Read LOG file: It allows reading the registered events in the module.
1. Select the option “Read LOG file”
through Up/Down buttons. Press OK
to continue
2. A new window will appear. It will
show the information about the
registered events in the module. Press
the following keys in order to scroll up
and down the screen: “up/down”.
- Delete LOG file: It allows deleting all events stored until this moment.
- Update FW: It allows carrying out the firmware update from the programmer.
- Global Update: It allows carrying out the update of all the modules that are interconnected at the same time.
- Factory default: This option restores the values by default of the transmodulator.
Read LOG file
N:00000 Status:FB
04/07/14 13:49:28
Low FE noise margin
TFF 310 CI
System
1.SW version info
2.Date / Time
3.Read LOG file
4.Delete LOG file
TFF 310 CI
Network options
1.Network name
2.TSID
3.NID
4.ONID
TFF 310 CI
System
1.SW version info.
2.Date / Time
3.Read LOG file
4.Delete LOG file