background image

User’s manual · TSQ 310 

 

         

- 4 -                TSQ  310                 version_en_1.1              FTE maximal 

 

1.4.2.

 

   Programming 

Below you will find the steps to follow in order to make the programming both from corresponding EVO and MINI field 
strength  meter as well as  from PRO 201.  
 
mediaMAX EVO / mediaMAX MINI 
In order to start programming the TSQ 310 transmodulator, you will have to go to “Tools” option through the key 8 of your 
field strength meter and to select the “Prog Transmodulators “option. 

 

 

 

Then, it will proceed to recognize the module and to show the main menu. In the “Prog. Transmodulators” are shown the 
different configuration options that this tool offers: 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

1.  Module selection  
The field strength meter allows carrying out the programming of one or several transmodulators from an only 
transmodulator. 

              

 

 

Without interconnection of modules. 

An only module connected 

Interconnection of several modules, you can select which 

modules you wish to program. 

 

 
 
 
 
 
 
 
 

Summary of Contents for TSQ 310

Page 1: ...changes of temperature 8 Never open the device by yourself due to electric risk In case of problems go always to qualified technicians 9 Never under no circumstances open the device when connected to...

Page 2: ...the module 4 LNC IN To connect to the LNC or to the LOOP OUT output of the previous module 5 LOOP OUT To connect to the ANT IN input of the next module 6 RS 232 Ethernet connector to cascade modules...

Page 3: ...t parameters 1 4 Programming TSQ 310 has two ethernet connectors In order to make the programming of the module you have to connect the corresponding programmer to PRO 201 connector You can make the p...

Page 4: ...on through the key 8 of your field strength meter and to select the Prog Transmodulators option Then it will proceed to recognize the module and to show the main menu In the Prog Transmodulators are s...

Page 5: ...r Selection of the local oscillator that you wish to use FI KU C K9750 K10000 K10600 K10700 K10750 K11250 K11300 K11325 Frequency MHz Transponder frequency that you wish to tune Symbol speed Symbol sp...

Page 6: ...g the bigger this value is the less interference between symbols that will be caused Typical Value according to rules DVB C 15 Options 15 13 5 Output configuration In this option you can configure the...

Page 7: ...nformation It allows you to visualize the basic information of the module model no of series firmware version etc Settings This option allows saving and loading the configuration of the module carryin...

Page 8: ...different options Auto The Meter decides where the data will be stored If there is external memory connected the Meter will store the data in it If not it will use the internal memory USB The Meter al...

Page 9: ...x Note It is not recommended to exceed the 85 of the maximum capacity of the multiplex due to the possible variability of the bits rate of the inputs services Recomendad capacity lower to 85 Excessive...

Page 10: ...ed and when the list of selected services is empty The receiver will have this state by default Always It selects the services automatically every time a new input carrier is tuned This state is only...

Page 11: ...satellite signal L O freq Local oscillator Selection of the local oscillator that you wish to use FI KU C K9750 K10000 K10600 K10700 K10750 K11250 K11300 K11325 Freq Input Frequency MHz Transponder f...

Page 12: ...C SYMBOL IN V SYMBOL OUT V 3 3 2 22000 8 Modulation QPSK 8PSK 16 QAM 32 QAM 64 QAM 128 QAM 256 QAM Number of bits per symbol 2 3 4 5 6 7 8 Modulation 16 QAM 32 QAM 64 QAM 128 QAM 256 QAM Symbol speed...

Page 13: ...is given Read log It allows reading the registered events in the module 1 Select the option Read LOG file through Up Down buttons Press OK to continue 2 Press OK again to show the log file 3 A new wi...

Page 14: ...function will allow the users who have a receiver with LNC support to make the ordination of channels automatically Select a channel through Left Right buttons and introduce the position Press the OK...

Page 15: ...I HDMI receiver that would decode free channels and also encoded channels if we insert a PCMCIA with the corresponding subscriber card In order to guarantee the right running of the different equipmen...

Page 16: ...AM 128 QAM 256 QAM Output symbol Rate 1 6 96 MS s Roll Off Factor 13 15 Output channels C2 C69 Output connectores Female F connector Output Level 80 dBuV Regulation margin 15 dB MIX Losses 1 dB Band s...

Reviews: