background image

 

Fume hoods 

Soldering irons

 

Specialized tools for wiring and tinning

 

Hand tools, consumables and workshop equipment

 

 

 

info@ftm-technologies.com 

 +33 (0)1 40 86 00 09 

 www.ftm-technologies.com

  

   

       

 
 

PC4NC 

         Plier for large diameter cable 
 
 

They are connected to the control box through a fast connector. 

Length of the connection cable is 1,05 m. 

Choice of electrodes 

 

The electrodes will be choosen according to the diameter of the wire and to the nature of insulation being 
stripped. 
 

Reference 

Designation 

Tightening of 

electrodes screws 

AWG 

EDT2P 

Flat wire electrodes 

32 Ncm 

8 to 28 

EEDT2 

Flat wire electrodes with 

notch 

32 Ncm 

8 to 28 

EEDT4 

Flat wire electrodes with 

double notch 

32 Ncm 

8 to 36 

EDT2PA/U 

Flat wire electrodes for 

large section 

56 Ncm 

< 8 

TEDT2 

Sheet metal electrodes 

with notch 

32 Ncm 

8 to 28 

EG182022 

Gauge electrodes 

Ø 

18, 20, 22 

 

3.

 

SAFETY INSTRUCTIONS

 

 

- Avoid putting the electrodes in contact with easily flammable parts. 

 

- Do not to touch the electrodes with the fingers (possibility of serious burns). 

 

- Do not put out the plier from the connector/control box, without having taken care of disconnecting the cord 

of power supply. 

 

4.

 

INSTALLATION

 

 

1 -   Put the control box on a plane and horizontal surface. 

 

2 -  Connect the clamp to the control box, this by simple twisting, the metal ring must swivel clockwise, then 

in the opposite direction, this until hearing small click. Ensure of its good connection while drawing slightly 
on the connector. 

 

3 -  Check that the length of the electric cord is compatible with the distance from the Block to the 
       mains supply. 

 

4 -  Check that this mains supply has AC current single-phase current with ground 230V ; 50 Hz. BDT3 TS  

allows any type of mains supply 110 

 230 V ; 50 

 60 Hz. It must be protected by a fuse from maximum 

6 A. 

 

5.

 

STARTING

 

 

- Check that the switch is in position 0. 

 

- Connect the socket to mains supply. 

 

- Check that the control knob of the temperature is in position minimum or LCD displays zero. 

Summary of Contents for BDT3A

Page 1: ...technologies com 33 0 1 40 86 00 09 www ftm technologies com 1 INSTRUCTIONS FOR USE THERMAL WIRE STRIPPING BDT3A BDT3 TS FTM Technologies thanks you for buying our thermal stripper 1 Cautions for use...

Page 2: ...d be supervised to ensure they do not play with the device 2 PRODUCT DESCRIPTION The thermal stripper is composed of two parts Power units BDT3A Technical data The carter is made of blue painted steel...

Page 3: ...putting the electrodes in contact with easily flammable parts Do not to touch the electrodes with the fingers possibility of serious burns Do not put out the plier from the connector control box with...

Page 4: ...ith the clamp closed Proceed in 2 stages make a first heating and a second one after having made 1 4 of turn Turning off Stop heating put the switch on position 0 on the control box If non used for a...

Page 5: ...cated maximum Spare parts recommended stock Fuse 2 A Quantity 2 Electrodes according to model employed Quantity 10 pairs Cord replacement If the power cord is damaged it must be replaced by the manufa...

Page 6: ...Fume hoods Soldering irons Specialized tools for wiring and tinning Hand tools consumables and workshop equipment info ftm technologies com 33 0 1 40 86 00 09 www ftm technologies com 6...

Page 7: ...ies com 7 Our Company Our know how has been with you for more than 100 years We serve more than a thousand companies every year in all sectors and allow them to have work tools adapted to their activi...

Page 8: ...at we master the maintenance and repair for a reduced environmental footprint Customized solutions A specific project we propose an ad hoc solution Showroom Presentation of our products and realizatio...

Reviews: