PC4NC
Plier for large diameter cable
They are connected to the control box through a fast connector.
Length of the connection cable is 1,05 m.
Choice of electrodes
The electrodes will be choosen according to the diameter of the wire and to the nature of insulation being
stripped.
Reference
Designation
Tightening of
electrodes screws
AWG
EDT2P
Flat wire electrodes
32 Ncm
8 to 28
EEDT2
Flat wire electrodes with
notch
32 Ncm
8 to 28
EEDT4
Flat wire electrodes with
double notch
32 Ncm
8 to 36
EDT2PA/U
Flat wire electrodes for
large section
56 Ncm
< 8
TEDT2
Sheet metal electrodes
with notch
32 Ncm
8 to 28
EG182022
Gauge electrodes
Ø
18, 20, 22
3.
SAFETY INSTRUCTIONS
- Avoid putting the electrodes in contact with easily flammable parts.
- Do not to touch the electrodes with the fingers (possibility of serious burns).
- Do not put out the plier from the connector/control box, without having taken care of disconnecting the cord
of power supply.
4.
INSTALLATION
1 - Put the control box on a plane and horizontal surface.
2 - Connect the clamp to the control box, this by simple twisting, the metal ring must swivel clockwise, then
in the opposite direction, this until hearing small click. Ensure of its good connection while drawing slightly
on the connector.
3 - Check that the length of the electric cord is compatible with the distance from the Block to the
mains supply.
4 - Check that this mains supply has AC current single-phase current with ground 230V ; 50 Hz. BDT3 TS
allows any type of mains supply 110
–
230 V ; 50
–
60 Hz. It must be protected by a fuse from maximum
6 A.
5.
STARTING
- Check that the switch is in position 0.
- Connect the socket to mains supply.