700-SDI-RADAR-300W-Man Rev 2 30 May 2022
14
/39
Part# 21370
Table 4-5: Retrieving Data from the Sensor
Function Data start
Addr
Data Length Data Range
Detail
0X03
0X0000
2 bytes
1~255
Read sensor id
0X0001
2 bytes
0
→
9600
1
→
38400
2
→
57600
3
→
115200
Read baud rate
0X0002
2 bytes
0
→
mm/s
1
→
m/s
2
→
other
Read set units type
0X0003
2 bytes
0-15000 (mm/s) Read instantaneous speed
0X0004
2 bytes
0-15000 (mm/s) Read averaged speed
0X0005
2 bytes
0-360
Read tilt angle
0X0006
2 bytes
0
→
IIR
1
→
Average
Read averaging type
0X0007
2 bytes
1-512
Read averaging length
0X0008
2 bytes
0
→
incoming
1
→
outgoing
Read flow direction
0X0009
2 bytes
0
→
both
1
→
incoming
2
→
outgoing
Read flow direction filter setting
0000A
2 bytes
0-100
Read sensitivity value
0X000B
2 bytes
0-2048
Read relative signal strength
0X000C
2 bytes
0
→
Normal
1
→
Rotated
sideways
Read preconfigured device placement
orientation (if it is rotated sideways or
not)
0X000D
2 bytes
451
Read firmware code 4.5.1
0X000E
2 bytes
0-8
Read defined gain sensitivity
0X000F
2 bytes
1,2,5,10,20,50,
100,200
Read current gain level
0X0010
2 bytes
0 – 65536
Read calculated water discharge
0X0011
2 bytes
0
→
ASCII64
1
→
NMEA
2
→
ASCIIV
3
→
AVIO
4
→
SDI12
Read RS-232 protocol type
0X0012
2 bytes
0
→
HS
1
→
MODBUS
Read RS-485 protocol type
0X0013
2 bytes
0
→
Disabled
1
→
Enabled
Is speed correction for tilt angle
enabled
0X0014
2 bytes
0
→
Sensor Err.
1
→
Sensor OK
Level sensor health indicator