HOW TO USE

1. Press On/Off button then LCD displays

188.8

M

(188.8

M

)

for 2

seconds. Keep pressing then displays last measurement, and releasing

98.6℉(37.0℃)for 1 second with ℉or℃ flashing respectively.

2. If ambient temperature is higher than 111.2

(44.0

),LCD displays H

(H

)and lower than 89.6

(32.0

) then displays L0

(L0

).

3. Disinfect the probe with alcohol then place the probe under/in:

3.1 Oral use: Place the probe under tongue and close the mouth about

1minute till temperature is stable. Normal temperature is 98.6

(36.7

).

3.2 Axillary use: Wipe armpit with dry towel then place the probe in

armpit firmly about 1 minute till temperature is stable. Normal

temperature is 98.0

(36.7

).

3.3 Rectal use: Lubricate the probe with water-soluble jelly like K-Y

jelly. Do not use petroleum jelly like Vaseline for easier

insertion.

Insert the probe into rectum about 1 CM (lower than 1/2 inch)

till the temperature is stable. Normal temperature is about 99.7

(37.6

)

.

4. The peak temperature is first time and stable for 16 seconds, then alarm

Bi voice for 4 seconds is followed.

4.1 The power will be shut off automatically if no temperature rising

Notes:

1. Use the probe may result in 0.2

(0.1

)difference with real

temperature.

2. It is suggested that rectal use t---thermometer does not use for axillary

and oral use for the hygienic reason.

The Blue Tooth function model is BT-A41CN-BT

Operation Method:

Install the APK accordance with the communication protocol into

the blue tooth signal receiving device such as mobile phone.

Activate the blue tooth signal receiving device such as mobile

phone to match with the blue tooth of infrared thermometer

Summary of Contents for BT-A41CN-BT

Page 1: ...Instruction for Use Digital Thermometer BT A41CN BT ...

Page 2: ...eeper to alarm the peak temperature 4 Auto self test and power auto shut off 5 With quick temperature response and high accuracy 6 Comparing with mercury thermometer without problems of both mercury pollution and glass broken SPECIFICATIONS Product Name Digital Thermometer Applied Models BT A41CN BT Temperature range 32 0 42 9 89 6 109 2 Low temperature display Temperature 32 0 C 89 6 F display Lo...

Page 3: ...consumption About 0 15mW for without backlight voice type Applied part type Type BF applied part IP classification IP22 IP22 The first number 2 Protected against access to hazardous parts with a finger and the jointed test finger of 12 mm Ф 80 mm length shall have adequate clearance from hazardous parts And protected against solid foreign objects of 12 5 mm Ф and greater The second number Protecte...

Page 4: ...h water soluble jelly like K Y jelly Do not use petroleum jelly like Vaseline for easier insertion Insert the probe into rectum about 1 CM lower than 1 2 inch till the temperature is stable Normal temperature is about 99 7 37 6 4 The peak temperature is first time and stable for 16 seconds then alarm Bi voice for 4 seconds is followed 4 1 The power will be shut off automatically if no temperature ...

Page 5: ...ed and put into service according to the EMC information provided and this unit can be affected by portable and mobile RF communications equipment 2 Do not use a mobile phone or other devices that emit electromagnetic fields near the unit This may result in incorrect operation of the unit 3 Caution This unit has been thoroughly tested and inspected to assure proper performance and operation 4 Caut...

Page 6: ...r supply network that supplies buildings used for domestic purposes Guidance and manufacture s declaration electromagnetic immunity The BT A41CN BT is intended for use in the electromagnetic environment specified below The customer or the user of BT A41CN BT should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance...

Page 7: ...strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in ...

Page 8: ...s may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people FCC compliance statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that ...

Page 9: ...t use the device or an electrode if it is damaged in any way The continuous use of a damaged unit may cause injury improper results or serious danger 4 If you have any problems with this device such as setting up maintaining or using please contact with SERVICE PERSONNEL of Fudakang Industrial Co Ltd 5 Don t open or repair the device by yourself 6 Please report to Fudakang Industrial Co Ltd if any...

Page 10: ...ANTY This thermometer is guaranteed for 5 years from the purchasing date under normal use The warranty does not cover the damage of improper use or the battery running out f the unit does not function properly due to defective parts or assembly we will repair it free of charge or replace with a new one Explanation of Symbols Symbol for CE Symbol for batch code Symbol for manufacturer Symbol for el...

Page 11: ...NG INDUSTRIAL Co Ltd 301 3rd Floor Block 1 No 60 Shangshuxia Road Changping Town Dongguan City Guangdong Province China EC Representative FANTRONIC COMPOSANTS Rue Jacques Laurent ZA Sud Est BP 11 85150 LA MOTHE ACHARD FRANCE Tel 33 2 51 08 89 20 Fax 33 2 51 08 86 25 Soft ware Version 1 3 Manual Version 2 0 ...

Reviews: