background image

 

- 10 -

the unit does not function properly due to defective parts or assembly, we will repair it free of 
charge or replace with a new one .We will provide circuit diagrams, component part lists, 
descriptions, calibration instructions to assist to service personnel in parts repair. 
 
Notes: 
If you have any problems with this device, such as setting up, maintaining or using, please 
contact with service personnel of 

FUDAKANG INDUSTRIAL CO.,LTD

. Don’t open or repair the 

device by yourself.   
Please report to 

FUDAKANG INDUSTRIAL CO.,LTD

  if any unexpected operation or events 

occur.  
After drop/ shock…,that may cause changes in the performance , please contact with 
service personnel of 

FUDAKANG INDUSTRIAL CO.,LTD

.  

Don’t open or repair the device by yourself.

  

Keep the device out of the reach of children/pets to avoid inhalation or swallowing of small 
parts.  
The device should be used only with the accessories recommended for use by the 
manufacturer.  
This device must only be serviced, repaired and opened by individuals at authorized sales 
centers . 
This device is not a life supporting me equipment 
 
Statement: Clinical accuracy characteristics and procedures are available from the 
manufacturer on request. 
 

STATEMENTS AND DECLARATIONS:

 

 
1. MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to 
be installed and put into service according to the EMC information provided in the ACCOMPANYING 
DOCUMENTS  
 
 
2. Wireless communications equipment such as wireless home network devices, mobile phones, 
cordless telephones and their base stations, walkie-talkies can affect this equipment and should be 
kept at least a distance d = 3,3 m away from the equipment. 
(Note. As indicated in Table 6 of IEC 60601-1-2:2007 for ME EQUIPMENT, a typical cell phone with 
a maximum output power of 2 W yields d = 3,3 m at an IMMUNITY LEVEL of 3 V/m) 
 

 

3. The manufacturer are available for request of circuit diagrams, component part lists, 

descriptions ,calibration instructions ,or other information that will assist service personnel to 

repair those parts of the device 

 

Summary of Contents for FT-F31

Page 1: ...1 Instruction for Use lnfrared Thermometer No contact Type FT F31 BT FT F32 BT FT F41 BT FT F42 BT FT F31 FT F32 FT F41 FT F42...

Page 2: ...r Measuring Temperature 9 Product Specification 10 Common question concerning forehead temperature 2 Product Overview This infrared Thermometer measure the temperature It can get more quick and accura...

Page 3: ...hermometer and then all displayed segments appear briefly as like on Figure 5 2B the displayed screen appears last measured temperature data please see on Figure 5 3B after few seconds automatically c...

Page 4: ...ymbol appear on the display and the temperature unit or blink then it s ready to measure please see on Figure 5 4C Take IR thermometer to aim at the target about 5 to 10 CM distance then press the SCA...

Page 5: ...ll 12 memories recall for FT F31 FT F31 BT FT F32 FT F32 BT Press SCAN button to display M on the displayed screen in the power off condition and then memory recall displays Press again SCAN button ke...

Page 6: ...90 Isopropyl alcohol IPA to clean up before or after use Avoid multiple using by different peoples for cross infection Note 1 Any solution dilution and method other than mentioned above might cause r...

Page 7: ...ressure 86 106 kPa Storage Condition 25 0 55 0 13 0 131 0 Rh 95 Pressure 86 106 kPa Battery type and battery life AAA 2pcs Suitable for FT F31 FT F31 BT FT F42 FT F42 BT AA 2pcs Suitable for FT F41 FT...

Page 8: ...etooth 4 1 BLE Bluetooth Modulation Type GFSK Specially Voice Function for Model no FT F31 FT F31 BT FT F41 FT F41 BT 1 When the IR thermometer is ready you can hear Please measure voice or other lang...

Page 9: ...ermometer for the reading 3 Why is a forehead temperature is more accurate than ear temperature Ear thermometers are considered inaccurate because the positioning of the probe in the ear canal might a...

Page 10: ...anufacturer This device must only be serviced repaired and opened by individuals at authorized sales centers This device is not a life supporting me equipment Statement Clinical accuracy characteristi...

Page 11: ...etween the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for...

Page 12: ...nterruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5...

Page 13: ...arked with the following symbol Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all sit...

Page 14: ...738 1 1 167 1 167 2 333 10 3 689 3 689 7 379 100 11 667 11 667 23 333 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estima...

Page 15: ...ng instructions IP22 Symbol for the IP classification Symbol for RF transmitters Manufacturer FUDAKANG INDUSTRIAL CO LTD Address No 8 Yinghe Road Yuanjiangyuan Management Zone Changping Town Dongguan...

Reviews: