LM2A Wall Mounted Solution
Page
7
of
20
Fuji Electric Europe GmbH
•
Do not touch the heat sink because it becomes very hot.
Doing so could cause burns.
•
The DC brake function of the inverter does not provide any holding mechanism.
Injuries could occur.
•
Ensure safety before modifying customizable logic related function code settings (U codes and related
function codes) or turning ON the "Cancel customizable logic" terminal command CLC. Depending upon
the settings, such modification or cancellation of the customizable logic may change the operation
sequence to cause a sudden motor start or an unexpected motor operation.
•
If any abnormality is found in the inverter or motor, immediately stop it and perform troubleshooting,
referring to the FRENIC-Lift LM2A series Reference Manual.
An accident or injuries could occur.
Maintenance and inspection, and parts replacement
•
Before proceeding to maintenance or inspection, turn OFF the power and wait at least 10 minutes. Make
sure that the charging lamp is turned OFF. Further, make sure, using a multimeter or a similar instrument,
that the DC link bus voltage between the terminals P(+) and N(-) has dropped to the safe level (+25 VDC
or below).
Otherwise, an electric shock could occur.
•
Always carry out the daily and periodic inspections described in the this manual. Use of the inverter for
long periods of time without carrying out regular inspections could result in malfunction or damage, and
an accident or fire could occur.
•
It is recommended that periodic inspections be carryout every one to two years, however, they should
be carried out more frequently depending on the usage conditions.
•
It is recommended that parts for periodic replacement be replaced in accordance with the standard
replacement frequency indicated in the this manual. Use of the product for long periods of time without
replacement could result in malfunction or damage, and an accident or fire could occur.
•
Contact outputs [30A/B/C] [Y5A/C] [Y4A/C] [Y3A/C] use relays, and may remain ON, OFF, or
undetermined when their lifetime is reached. In the interests of safety, equip the inverter with an external
protective function.
Fire or an accident could occur.
•
Maintenance, inspection, and parts replacement should be made only by qualified persons.
•
Take off the watches, rings and other metallic objects before starting work.
•
Use insulated tools.
Otherwise, an electric shock or injuries could occur.
•
Never modify the inverter or any other component of the cabinet. Never modify the internal cabinet wiring.
Doing so could cause an electric shock or injuries.
Disposal
•
Treat the inverter as an industrial waste when disposing of it.
Otherwise injuries could occur.
GENERAL PRECAUTIONS
Drawings in this manual may be illustrated without covers or safety shields for explanation of detail parts.
Restore the covers and shields in the original state and observe the description in the manual before starting
operation.