3-10
If the full-menu mode is selected, pressing the or key will cycle through the menus.
With the key, you can select the desired menu item. Once the entire menu has been
cycled through, the display will return to the first menu item.
3.4.1 Setting up the function codes – "Data Setting"
Menu #1 "Data setting" in Programming mode allows you to set function codes for making the
inverter functions match your needs.
To set function codes in Menu #1 "Data setting," it is necessary to set function code E52 data to "0"
(Function code data editing mode) or "2" (Full-menu mode).
The table below lists the function codes available in the FRENIC-Mini. The function codes are
displayed on the LED monitor on the keypad as shown below.
Table 3.7 List of FRENIC-Mini Function Codes
Function code
group
Function code
Function
Description
F codes
F00 to F51
Fundamental functions
To be used for basic motor running.
E codes
E01 to E99
Extension terminal
functions
To be used to select the functions of the
control circuit terminals.
To be used to set functions related to
the LED monitor display.
C codes
C01 to C99
Control functions of
frequency
To be used to set application functions
related to frequency settings.
P codes
P02 to P99
Motor 1 parameters
To be used to set special parameters for
the motor capacity, etc.
H codes
H03 to H98
High performance
functions
To be used for high added value func-
tions and complicated control, etc.
A codes
A01 to A52
Motor 2 parameters
To be used to set specific parameters
for the motor capacity, etc.
J codes
J01 to J72
Application functions
To be used for PID control and brake
signals.
y codes
y01 to y99
Link functions
To be used for communications
Refer to Chapter 5 "FUNCTION CODES" for details on the function codes.
Function code group