Error Code
475
Problem
Solvin
g
15
017-729
[Cause]
When the machine is used as a print job storage device, print job sending was stopped
temporarily because the number of jobs in the machine exceeded the maximum
receivable volume or the space for spool data was insufficient.
[Remedy] Take one of the following measures:
z
Set to spool data to the hard disk from the setting of the storage destination machine.
z
Set [IPP] under [Properties] > [General Setup] > [Memory Settings] to [Spool to Hard
Disk] by CentreWare Internet Services.
z
Wait for a while and send the job again.
017-730
[Cause]
When the machine is used as a print job storage device, the computer failed to send a
job to the machine because a network error occurred.
[Remedy] Confirm the followings:
z
The network cable is connected properly.
z
The storage destination machine is powered on.
z
The IPP port of the storage destination machine is enabled.
If the error still is not resolved, contact our Customer Support Center.
017-731
[Cause]
Unable to connect to the POP server.
[Remedy] Confirm the followings:
z
The IP address of the POP server is set on the machine.
z
The network cable is connected properly.
017-732
[Cause]
When the machine is used as a print job storage device, the computer failed to send a
job because the machine is off-line.
[Remedy] Press the <Machine Status> button of the storage destination machine, and set [Print
Mode] to [On-line] on the [Machine Information] screen. If the error still is not resolved,
contact our Customer Support Center.
017-733
[Cause]
When the machine is used as a print job storage device, an internal error in the software
is occurred while the job sending to the machine.
[Remedy] Execute the operation again. If the error still is not resolved, contact our Customer
Support Center.
017-734
[Cause]
An internal error occurred during processing the AirPrint data.
[Remedy] Send the print job again by using the printer driver or software other than AirPrint. If the
error still is not resolved, contact our Customer Support Center.
017-735
[Cause]
Device usage is prohibited.
[Remedy] Execute the operation again. If the error still is not resolved, contact our Customer
Support Center.
017-737
[Cause]
Data could not be sent due to memory capacity shortage.
[Remedy] Have your system administrator stop or delete the unnecessary plug-ins. If the error still
is not resolved, switch off the machine power, make sure that the touch screen is blank,
and then switch on the machine power. If the same message is displayed again, contact
our Customer Support Center.
017-738
017-739
[Cause]
Data could not be sent due to an internal error.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. If the same message is displayed again, contact our Customer
Support Center.
017-740
[Cause]
Data could not be sent due to a plug-in activation failure.
[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch
on the machine power. If the same message is displayed again, contact our Customer
Support Center.
Error Code
Cause and Remedy
Summary of Contents for ApeosPort-V 4070
Page 1: ...ApeosPort V 5070 ApeosPort V 4070 DocuCentre V 5070 DocuCentre V 4070 Administrator Guide ...
Page 13: ...13 EP System 704 Glossary 705 Index 707 ...
Page 14: ...14 ...
Page 40: ...1 Before Using the Machine 40 Before Using the Machine 1 ...
Page 108: ...4 Machine Status 108 Machine Status 4 ...
Page 316: ...7 Printer Environment Settings 316 Printer Environment Settings 7 ...
Page 348: ...9 Scanner Environment Settings 348 Scanner Environment Settings 9 ...
Page 356: ...10 Using IP Fax SIP 356 Using IP Fax SIP 10 ...
Page 368: ...12 Using the Server Fax Service 368 Using the Server Fax Service 12 ...
Page 384: ...13 Encryption and Digital Signature Settings 384 Encryption and Digital Signature Settings 13 ...
Page 582: ...15 Problem Solving 582 Problem Solving 15 ...
Page 718: ...716 Index ...