15 Problem Solving
510
Pro
b
lem
So
lv
in
g
15
026-702
[Cause]
The number of accesses from the LDAP server to the machine by Address Book
operation exceeded the machine's processing capability.
[Remedy] Wait for a while and execute the operation again. If the error still is not resolved, contact
our Customer Support Center.
026-703
[Cause]
Authentication is canceled when adding documents during faxing or scanning.
[Remedy] Authenticate when adding documents.
026-704
[Cause]
An error occurred during processing DocuWorks documents.
[Remedy] Print using the print driver (PCL, etc.) from DocuWorks Viewer.
026-705
[Cause]
Unable to process for DocuWorks documents because of insufficient memory space.
[Remedy] Change the [Image Quality] setting from [High Resolution] to [High Quality], or from
[High Quality] to [Standard]. Or, add memory. If the error still is not resolved, increase
memory. If the problem persists even after adding memory to the maximum capacity,
print using the print driver (PCL, etc.) from DocuWorks Viewer.
026-706
[Cause]
Attempted to print a DocuWorks document of which printing is prohibited.
[Remedy] Release the print prohibited settings using DocuWorks Viewer, and then execute the
operation again.
026-707
[Cause]
When processing password-protected DocuWorks documents, the password entered
does not match that of the DocuWorks document.
[Remedy] Set the correct password on ContentsBridge.
026-708
[Cause]
Exceeded the maximum limit for the scan data size that can be stored for one job with
Store & Send Link.
[Remedy] Take one of the following measures:
1)Reduce the resolution (scan quality) of the scan parameters and execute the
operation again.
2)Reduce the image with magnification of the scan parameters (such as A3 > A4) and
then execute the operation again.
3)If [Store & Send Link - Maximum File Size] is set to a small value, increase the value.
026-709
[Cause]
The capacity of the hard disk that can be used to store scan data with Store & Send Link
is insufficient.
[Remedy] Wait around one day, and when capacity becomes available as a result of the
automatic deletion of files, execute the operation again.
026-710
[Cause]
The machine has received and e-mail encrypted by S/MIME, but does not support the
encryption method.
[Remedy] Take one of the following measures:
z
Ask the sender to send the e-mail encrypted by 3DES.
z
Disable the FIPS140 validation mode of the machine.
026-711
[Cause]
Exceeded the maximum size allowed for a multi-page file when scanning.
[Remedy] Take one of the following measures:
1)Reduce the resolution (scan quality) of the scan parameters and execute the
operation again.
2)Reduce the number of document pages and then execute the operation again.
The maximum size is 2 GB for TIFF, XPS, and PDF, and 1 GB for XDW.
Note
•
XPS stands for XML Paper Specification.
026-712
[Cause]
An error occurred while operating from CentreWare Internet Services.
[Remedy] Retry after waiting for a while.
Error Code
Cause and Remedy
Summary of Contents for ApeosPort-V 6080
Page 1: ...ApeosPort V 7080 ApeosPort V 6080 DocuCentre V 7080 DocuCentre V 6080 Administrator Guide ...
Page 13: ...13 Activity Report 727 EP System 731 Glossary 732 Index 735 ...
Page 14: ...14 ...
Page 62: ...2 Paper and Other Media 62 Paper and Other Media 2 ...
Page 88: ...3 Maintenance 88 Maintenance 3 ...
Page 110: ...4 Machine Status 110 Machine Status 4 ...
Page 296: ...5 Tools 296 Tools 5 ...
Page 346: ...9 Scanner Environment Settings 346 Scanner Environment Settings 9 ...
Page 354: ...10 Using IP Fax SIP 354 Using IP Fax SIP 10 ...
Page 366: ...12 Using the Server Fax Service 366 Using the Server Fax Service 12 ...
Page 382: ...13 Encryption and Digital Signature Settings 382 Encryption and Digital Signature Settings 13 ...
Page 734: ...16 Appendix 734 Appendix 16 ...
Page 744: ...Index 744 Index ...