86
Optional Units Manual
Circuit Breaker Switch
If the machine will be moved or unused for an extended period of
time, turn off the switch by pressing.
Note
When fault current is detected, the circuit breaker is automati-
cally turned off to discontinue the electrical flow. Do not touch
the breakers under normal condition. For information on fault
current, refer to the
Safety Notes
.
Specifications
Item
Specification
Trim / square fold
Paper size
Size and weight comply with the Booklet Tray attached to Finisher D6 with
Booklet Maker.
Paper weight
Capacity
Trim
Saddle Stitch
30 sheets
Bi-Fold
5 sheets
Square Fold
Saddle Stitch
30 sheets
Note
The values are based on C90.
Square back binding is not supported for Bi-Fold or Saddle Stitch of less than 5 sheets.
Trimming size
2 - 20 mm
Booklet tray capacity One set = 15 bind and above
20 sets
One set = 16 bind and below
15 sets
Note
The values are based on a paper less than 80 g/m
2
.
Power supply
Power consumption
Power supply 100 - 240 V AC±10%
100 V
0.8 A, 50 Hz or 60 Hz
240 V
0.4 A, 50 Hz or 60 Hz
Peak
100 V
80 W
240 V
96 W
Dimensions
Width 1,066 x Depth 725 x Height 552 mm (when attached to the machine)
Weight
100 kg
Breaker switch
TEST button