SS1807-N002
Failure Analysi
-
18/64
Display
error
code
Classification
level
Display message
(occurrence, response)
Display message
(guidance to
error)
Estimated cause
Trigger of message display
Service response
207
Information
Searching
Please wait for a while.
⇒
To cancel,
press the [Enter]
key.
Searching images on memory
Memory searching
In the case that searching starts
on the search screen with the
setting of including images in
external memory: If searching
does not finish after waiting a
while, back up the contents of the
inserted external memory in
Windows PC, etc., perform
physical-formatting instead of
quick-formatting of external
memory. Copy the backup
contents in the external memory,
and insert the external memory
to try searching again.
In case of repetitive errors after
that, replace the external
memory, USB PCB.
When searching starts on the
search screen with the setting of
including internal memory, FTP
not-transferred backup images,
and FTP-transferred backup
images: Replace the main PCB
210
Warning
Cannot be saved in
Internal Memory.
Saving in internal memory was
tried.
After performing backup of the
contents of internal memory in
Windows PC, external memory,
etc., initialize the internal memory
and then try back up again.
In case of repetitive errors after
that, replace the main PCB.
211
Information
Saving data in Internal
Memory.
Please wait for a while.
Internal memory save processing
after the inspection has finished
Same as on the left
Wait till saving data is finished
If saving data is not completed,
replace the main PCB.
212
Warning
Set External Memory.
⇒
If this message
appears even
when External
Memory is set,
contact the sales
agent or our
service
representatives.
The states of external memory
are as follows.
(1) Not inserted
Same as on the left
In the case of repetitive errors
even when an external memory
is inserted, replace the external
memory, USB PCB, harness
(Main-IO)
Summary of Contents for EP-6000
Page 1: ...Processor EP 6000 FV693A Service Manual SR1807 N002 Ver 1 Oct 2018 ...
Page 5: ...SS1807 N002 General Table of Contents 1 1 General Table of Contents ...
Page 13: ...SS1807 N002 Caution in Safety 1 12 Caution in Safety ...
Page 25: ...SS1807 N002 Product Specifications 1 11 Product Specifications ...
Page 36: ...SS1807 N002 Instruction of System 1 106 Instruction of System ...
Page 133: ...SS1807 N002 Instruction of System 98 106 ELC PCB Patient PCB APC PCB APC PCB APC PCB DC Pump ...
Page 139: ...SS1807 N002 Instruction of System 104 106 9 4 Outline of PCB roles ...
Page 142: ...SS1807 N002 Failure Analysis 1 64 Failure Analysis ...
Page 206: ...SS1807 N002 Checkup Replacement and Adjustment 1 137 Checkup Replacement and Adjustment ...
Page 343: ...SS1807 N002 Service Parts List 1 19 Service Parts List ...
Page 352: ...SS1807 N002 Service Parts List 10 19 2 2 2 4 1 3 3 2 3 3 6 5 ...
Page 356: ...SS1807 N002 Service Parts List 14 19 1 3 3 4 1 2 1 3 X 4 1 3 3 4 3 3 ...
Page 358: ...SS1807 N002 Service Parts List 16 19 3 1 2 1 ...
Page 360: ...SS1807 N002 Service Parts List 18 19 Fig 09 5 4 2 3 1 ...
Page 362: ...SS1807 N002 Periodical Maintenance 1 15 Periodical Maintenance ...
Page 377: ...SS1807 N002 Installation 1 68 Installation ...
Page 445: ...SS1807 N002 ...