FinePix S5800/S800 Service Manual
5-1
5. Inspection
Confidential: FUJIFILM Service Center Use Only
Parts number
Measuring equipment
Remarks
Power supply
AC adapter (AC-5V), Regurated power supply
Digital voltmeter
For general use
Ammeter
For general use (able to measure 1mA or less)
xD-Picture card
For general use
TV Monitor
TV monitor, minimum resolution 600 lines
ZJ00580-100
Power Cable jig
Common with adjustment JIG
ZPU0512-100
SD CARD ULTRA2 1GB
To check SD card recording
ZJ00525-100
Macro Chart
Resolution confirmation
ZJ00885-100
LCD Inspection Data
For LCD inspection
ZJ01080-100
FxS5700/S700 Battery jig Battery low check
5. Inspection
5-1.
Required Measuring Equipment
5-2.
Connection of Measuring Equipment
Use Power Cable jig.
The output current of the Regurated power supply must not become 2.5A or more.