FinePix S5800/S800 Service Manual
5-4
5. Inspection
Confidential: FUJIFILM Service Center Use Only
Sequemnce
Item
Mode
Preparations for adjustment
(measurement points, subject, other)
Method of adjustment
(VRs, waveforms, required values)
Measuring
equipment and jigs
Measurement points
(VRs, positions)
9
Erase mode check Erase
(1) Select "Erase" -> "Erase
all" from the menu and
then press the "OK" button.
(2) Press the "OK" button
again.
(1) Check that an erase
message such as the
following appears:
Japan: “
OK?”
Overseas: “ERASE ALL
OK?”
China: “
OK?”
(2) Check that the recorded
images are erased.
10
Flash check
(1) Set the flash mode to
FORCED FLASH.
(2) Check that the flash pops
up when a picture is taken.
(1) Press the 4-way button
(right) and check that
** appears on the LCD
monitor.
11
LCD dust/defect
check
Playback
(1) Insert a standard xD-
Picture card.
(2) Play back a completely
black image.
(3) Play back a completely
white (75%) image.
(4) Change the setting with the
EVF/LCD button.
(2) Check that there are no
noticeable dust flecks or
stains (bright spots) on the
screen.
(3) Check that there are no
noticeable dust flecks or
stains (smears, flashing
points, etc.) on the screen.
(4) Play the above 2 frames
and perform the same
checks.
ZJ00885-100
12
Battery low check
Movie
(1) Connect the power supply
jig to the Battery terminal.
(2) Set the power supply
voltage.
(3) Set the Mode dial to Movie
or Camera mode and turn
the camera on.
(4) Set the pre-end voltage.
(5) Set the end voltage.
(2) 5.0 ± 0.1 V
(3) Check that the camera
starts up normally.
(4) 4.6 ± 0.1 V
Check that the battery low
warning appears.
(5) 4.47 ± 0.10 V
Check that the camera
turns off.
ZJ01080-100
13
Current
consumption check
Auto mode
LCD-ON
(1) Connect the power supply
jig to the Battery terminal.
(2) Set the power supply
voltage.
(3) Set the Mode dial to AUTO
and turn the camera on.
(4) After the LCD live image
appears, check the current
consumption.
(2) 5.0 ± 0.1 V
(4) 500 mA or less
(Stable state -> IRIS/
FOCUS does not operate)
ZJ01080-100
14
Checking standby
current
OFF
(1) Connect the power supply
jig to the DC_IN terminal.
(2) Set the power supply
voltage.
(3) Check the standby current
when the power is turned
OFF.
(2) 5.0 ± 0.1 V
(3) 0.2 mA or less
ZJ00580-100