13
FinePix4800Zoom(U/E/EG) SERVICE GUIDE
4. Adjustment and Inspection
4. Adjustment and Inspection
4-1. Important point Adjustment when Replacing Major Parts
Check and adjust of the items indicated by O in the table below when replacing the main PWB assembly,
DC PWB assembly, ST CONST, ST PWB unit, XE PWB unit, lens CONST, mode dial assembly, and B/W
LCD.
Note that adjustment is not required when units other than those shown below are replaced.
4-2. Preparations for Adjustment
4-2-1. Required Measuring Equipment
*1 Adjust in the following order when replacing the Lens CONST.
CCD defect data write/OFD adjustment
→
Picture adjustment
→
AF adjustment
→
Flash adjustment
*2 Adjust the Flash following Picture adjustment.
*3 As the CCD defect data is supplied as a pair with the CCD, the CCD defect data cannot be attached to the main
PWB assembly supplied as after-service parts. When replacing the main PWB assembly therefore, the method of
adjustment (method of repair) for ‘CCD defect data write/OFD adjustment’ is as follows.
(1) Remove the EEPROM (IC314) from the main PWB assembly of the unit to be repaired.
(2) Install the EEPROM (IC314) removed in (1) in the after service main PWB assembly.
(3) Make all adjustments other than CCD defect data write/OFD adjustment.
Measuring equipment
Remarks
Monitor TV
Regulated power supply
Pattern box
PTB450 or equivalent
Waveform monitor
Used for function checks
Digital voltmeter
PC
Used for various adjustments and operation checks (PC-AT compatible, Windows 98)
Brightness meter
LS-110 (Minolta) or equivalent
Color temperature meter
Color Meter IIIF (Minolta) or equivalent
MAIN PWB(*3)
DC PWB
ST CONST
ST PWB
XE PWB
LENS CONST(*1)
MODE DIAL
B/W LCD
Mode dial/battery adjustment
DC jack voltage adjustment
Display LCD adjustment
CCD defect data/OFD adjustment
(*3)
Picture adjustment
AF adjustment
Flash adjustment (*2)
End setting
Required for all when replacing and adjusting the above parts. See P19 and P29 for details of termination setting.
Replacement parts
Adjustments
4-2-2. List of Jig Used
Productname/type name
Pats.No
Use
Remarks
FilterLB140
ZJ00006-100
Camera System adjustments
Common with the DS-30/DS-20/DS-7
AF Chart
ZJ00477-100
AF adjustment
Common with the FInePix6800Zoom
Close_up lens(f=600mm)
ZJ00007-100
AF adjustment
Common with the 8mmVTR/MX500/MX600
Lens holder
ZJ00008-100
AF adjustment
Common with the 8mmVTR/MX500/MX600
Stand
ZJ00009-100
AF adjustment
Common with the 8mmVTR/MX500/MX600
Base plate
ZJ00010-100
AF adjustment
Common with the 8mmVTR/MX500/MX600
Gray Chart(Reflective type)
ZJ00254-100
Flash adjustmen
Common with the MX700/MX500
USB cable
FZ03529-100
For PC adjustment
Common with the FinePix4700zoom
CD-ROM
FZ04059-101
For inspection
bundled software
Power cable jig
ZJ00213-100
System adjustment
Common with the DS-10/FinePix1500
FinePix4800Zoom
ZJ00494-100
For PC adjustment
Operates only on Win98 English OS
PC adjustment software
AC adapter(AC-5VH)
-----------------
Adjustment overall
Accessories
DSC jig driver setup
ZJ00476-100
For PC setup
DSC jig driver setup
Li BATT jig
ZJ00226-100
System adjustment
Common with the MX1700