4. Adjustment and Inspection
Cautions When Adjusting
1) Terminal Setting returns the camera from the Jig mode to the Product Mode (see P29).
Terminal Setting is required when using the PC adjustment software, even when replacing boards or units
other than those noted above. Failure to run Terminal Setting will prevent identification as Mass Storage
when the camera is connected to the PC, and prevent communication with the PC.
2) As power from the DC jack, or from the lithium battery jig, may be used for FinePix 4800Z adjustment, it is
possible that the power supply may be changed during adjustment. When changing the power supply, first
remove the DC jack, and then insert the lithium battery jig (or the reverse).
Changing the power supply occurs while the PC adjustment software is running on the start screen (Fig.2, P20).
The PC adjustment software will generate an error if the power supply is changed while it is running, or in
the worst case may result in the PC hanging up.
3) When all adjustment have been completed, always check that the camera is identified as Mass Storage.
4) The values resulting from adjustment as shown on the PC screens ( Fig.4, Fig.6, Fig.7, Fig.10, Fig.15,
Fig.18, Fig.21, Fig.22, Fig.23) on the following pages cannot be used for comparison with adjustment
data.
<Step 5>
Select Hardware from the Customize Setup Screen
(Fig.I-(1)). Setup as follows on the Hardware menu
(Fig.I-(2)).
Item
Setup. details
Debug mode
Select Ignore Focus
<Step 6>
When setup on the three menus noted above (EVR,
Etc, Hardware) is complete, click on Apply (Fig.I-(3))
on the Customize dialog screen to finish.
After the setup has been applied, further setup is un-
necessary.
Note:
Setting Disable OKNG Display to OFF on the screen
shown in Fig.H displays OK on the screen if adjustment
is OK, and NG if not (either setting may be entered).
<Fig.I> Hardware Dialog Box Screen
(1)
(2)
(3)
Apply