29
FinePix4800Zoom(U/E/EG) SERVICE GUIDE
4. Adjustment and Inspection
<Fig.27> End Setting Start Screen
4-3-14. [E]: End Setting
(destination setting, USB ID write, product mode setting)
O The End setting consist of the following settings.
*
destination
setting
* USB ID write
* Product mode setting (mass storage identification)
O The setting must always be run when the adjust-
ment software is terminated. Failure to run Termi-
nal Setting will prevent identification as Mass
Storage when the camera is connected to the PC.
O USB ID write details
1) USB ID write requires that the USB device (in this
case FinePix 4800Z) be unique throughout the world.
For this reason, each device has a unique ID as deter-
mined by the USB standard. If multiple devices with
the same USB ID are connected to a single PC, the
PC will be unable to identify each USB device, thus
preventing operation.
2) Automatically written USB IDs are as follows.
Numbers in ( ) indicate decimal numbers. Other numbers are
ASCII numbers.
Select E on the Adjustment Items Select Screen.
When the E key is pressed on the PC keyboard the
End Setting Start Screen (Fig.27) appears. Proceed
with the END setting in accordance with the instruc-
tions on the PC screen. The adjustment procedure
and description are given below.
<Step 1>
Press E on the keyboard to displaying the END Setting
Start Screen(Fig.27), and Press the Enter Key.
After pressing ENTER KEY of PC, the screen where the
product model is selected Screen(Fig28).
Item
Details
Repair Date
Date information is acquired from
the PC and written.
Administrator ID
C(43)
Repair
<U_model>
Station
U.S.:61(a)
Canada:62(b)
Hawaii:63(c)
Taiwan:64(d)
Others:65(e)
<E_EG model>
England:66(f)
Germany:67(g)
France:68(h)
Spain:69(i)
Italy:6A(j)
Netherlands:6B(k)
Belgium:6C(l)
Sweden:6D(m)
Switzerland:6E(n)
Norway:6F(o)
Finland:70(p)
Singapore:71(q)
Others:72(r)
Repair
A serial No. is assigned
SerialNo.
automatically and written
<Fig.28> product model is selected Screen