4.Adjustments and Check
FinePix6800Zoom(U/E/EG) SERVICE GUIDE
Initial Adjustment
Page
Add Purpose
Name
Function (Contents)
value
value
1
C4h
E_PREVIEW_TIME Not used (area for use with subsequent models)
00h
1
C5h
E_CCD_REC
CCD data recording function (0: Not installed, 1: Installed)
00h
1
C6h
E_COMP_TYPE
No compression/Compression
00h
1
C7h
E_MULTI_DOWN
Split load selector (0: No split load, 1: Split load)
01h
1
C8h
E_TFD_LG56
Not used (area for use with subsequent models) TFD register 56
00h
1
C9h
E_TFD_LG57
Not used (area for use with subsequent models) TFD register 57
00h
1
CAh
E_TFD_LG58
Not used (area for use with subsequent models) TFD register 58
00h
1
CBh
E_TFD_LG59
Not used (area for use with subsequent models) TFD register 59
00h
1
CCh
E_EZ_STEP
Number of pixels for horizontal adjustment for each digital zoom step
40h
1
CDh
E_EZ_2TO4
Transition point from 1/4 thinning-out to 1/2 thinning-outdigital zoom (zoom code value)
17h
1
CEh
E_EZ_4TO2
Transition point from 1/2 thinning-out to 1/4 thinning-outdigital zoom (zoom code value)
11h
1
CFh
E_PWON_TV
Fixed TV value at power ON (TV x 10, Enabled: 44~100, AE when disabled)
32h
1
D0h
Set/EEP
E_MAX_BPS
Maximum Baud rate
00h
1
D1h
E_SETMODE
Set mode
02h
1
D2h
E_ROMSUM_H
ROM sum value (high)
00h
1
D3h
E_ROMSUM_L
ROM sum value (low)
00h
1
D4h
E_SUM_H
EEPROM check sum
AAh
1
D5h
E_SUM_L
EEPROM check sum
55h
1
D6h
E_COUNTRY1
OEM
00h
1
D7h
E_COUNTRY2
Destination (0: COMMON, 1: J, 2: U, 3: E, 4: EG)
00h
1
D8h
E_SETNAME
Set name (0:COMMON,1:SU10,2:SU20,3:SU30,4:SU40,5:SU50,6:SU60,7:SU70)
00h
1
D9h
E_EEP_CHK
EEPROM check
00h
1
DAh
E_EEP_ERR
EEPROM error flag
00h
1
DBh
E_EEP_WP
EEPROM write protect
00h
1
DCh
E_EEP_INI
EEPROM initialization flag (bits correspond to pages B0
→
P0 ... B7
→
P7)
00h
1
DDh
E_EEP_RE_RD
Number of EEPROM re-load intervals
00h
1
DEh
E_MTREVROFF
EVR value at motor drive OFF
C1h
1
DFh
E_TGSEL
TG pattern data select (1: EEPROM, Other: ROM)
00h
1
E0h Power supply
E_PREEND_CHK
Battery pre-end detection time (x 50msec)
0Ah
1
E1h
E_BATTEND_CHK
Battery end detection time (x 50msec)
0Ah
1
E2h
E_BATT_EM_TIM Forced end voltage detection time (number of successive matches)
00h
1
E3h
E_BATT_PREEND Battery pre-end (3.4V)
6Bh
O
1
E4h
E_BATT_END
Battery end (3.2V)
65h
O
1
E5h
E_AD_REF
AD reference voltage based value
D9h
O
1
E6h
E_BATTLV3
Battery remaining level 3 (battery 1/2: 3.55V)
70h
O
1
E7h
E_BATT_WARNING Battery malfunction diagnosis voltage (2.0V)
3Fh
1
E8h
E_CHARGV1
Charging check voltage 1 (2.9V)
A0h
1
E9h
E_CHARGV2
Charging check voltage 2 (3.92V)
DEh
1
EAh
E_CHARGV3
Charging check voltage 3 (4.02V)
E3h
1
EBh
E_CHARGV4
Charging check voltage 4 (4.20V)
FAh
1
ECh
E_DCV1
DC Jack voltage 1 (4.5V)
95h
1
EDh
E_DCV2
DC Jack voltage 2 (5.8V)
C0h
O
1
EEh
E_BATT_HIGH
Abnormal power supply voltage (5.7V)
B7h
O
1
EFh
E_BATT_EM_END
Forced end voltage
00h
1
F0h
E_PWRSAVE_TIM
Powersave mode entry time
1Eh