7
2
5.Troubleshooting
FinePix6800Zoom(U) SERVICE GUIDE
5.Troubleshooting
The repair methods for expected troubles are shown in the following table, so please refer to it when
making repairs.
Content of Trouble
Cause
Treatment Method
1 B/W LCD is not displayed.
Half insertion connector(CN901)
Re-insertion of CN901
of KEY PWB.
2 Voice does not go out.
Connector(CN701)uninsertion
Re-insertion of CN701
of MAIN PWB.
Half insertion of FFC(M204)
Re-insertion of FFC(M204)
3 Power supply does not enter.
Half insertion connector(CN902)
Re-insertion of CN902
of KEY PWB.
4 DISP key is not effective.
SW903 solder putting is defective
SW903 solder adjustment
of KEY PWB.
.
5 ZOOM error display appears.
Half insertion (CN102 or CN104)
Re-insettion of (CN102 or CN104)
or it becomes dirty.
or it cleans it.
6 USB communication is defective.
Connector(CN653:USB Connector)
CN653 solder adjustment
solder bridge of DC PWB.