Cleaning the Scanner Power Supply Section Air Filter
The scanner power supply section air filter is provided to ensure that clean air is
introduced into the power supply section. Clean it once a week.
IMPORTANT
If the scanner power supply section air filter is clogged, the temperature in the power supply
section will rise, causing circuit boards to malfunction.
q
Turn OFF the power to the scanner. (See
subsection 5.2.1.)
w
Remove the scanner power supply section
air filter.
e
Wash the air filter in tap water.
r
Allow the air filter to dry completely, then
reinstall it in the reverse order of removal.