5
PARAMETERS
5-46
Control system setting parameters #40 through #42
No.
Name
Setting range
Initial value
Change
40
Position controller gain 1
1 to 1000 [rad/sec] (in 1 increments)
77
Always
41
Speed response 1
1 to 1000 [Hz] (in 1 increments)
57
Always
42
Speed controller
integration time 1
1.0 to 1000.0 [msec] (in 0.1 increments)
25.9
Always
Control system setting parameters #45 and #46
No.
Name
Setting range
Initial value
Change
45
Feed forward filter time
constant
0.0 to 250.0 [msec] (in 0.1 increments)
12.9
Always
46
Torque filter time constant
0.00 to 20.00 [msec] (in 0.01 increments)
0.31
Always
These parameters are automatically updated when “auto tuning” or “semi-auto tuning” is selected at
basic setting parameter #5.
Specify them when “manual tuning” is selected.
Tuning mode
No.
Name
0: Auto
1: Semi-auto
2: Manual
06
Load inertia ratio
-
¡
¡
07
Auto tuning gain
¡
¡
×
40
Position controller gain
-
-
¡
41
Speed response
-
-
¡
42
Speed controller integration time 1
-
-
¡
45
Feed forward filter time constant
-
-
¡
46
Torque filter time constant
-
-
¡
*
¡
: Parameter which must be set
-
: Parameter which may not be set (The value is automatically calculated inside the
amplifier and the result is reflected on the parameter.)
×
: The parameter has no effect even if it is set.
Summary of Contents for GYN101CAG-G09
Page 1: ...FUJI AC SERVO SYSTEM USER S MANUAL MEH395 ...
Page 2: ......
Page 10: ......
Page 20: ...1 Outline 1 10 MEMO ...
Page 21: ...2 1 Servomotor 2 2 Servo amplifier INSTALLATION ...
Page 32: ...2 INSTALLATION 2 12 MEMO ...
Page 46: ...3 WIRING 3 14 MEMO ...
Page 52: ...3 WIRING 3 20 MEMO ...
Page 64: ...3 WIRING 3 32 MEMO ...
Page 65: ...4 1 Test operation in two stages 4 2 First stage 4 3 Second stage TEST OPERATION ...
Page 70: ...4 TEST OPERATION 4 6 MEMO ...
Page 85: ...PARAMETERS 5 5 15 MEMO ...
Page 132: ...6 ADJUSTMENT OF SERVO 6 8 MEMO ...
Page 164: ...8 KEYPAD PANEL 8 18 MEMO ...
Page 186: ...9 INSPECTION AND MAINTENANCE 9 22 MEMO ...
Page 226: ...11SPECIFICATIONS 11 14 MEMO ...
Page 234: ...11SPECIFICATIONS 11 22 Servo amplifier Unit mm Unit mm Unit mm ...
Page 235: ...APPENDIXES Inertia moment calculation Load torque Timing chart ...
Page 250: ...APPENDIXES Appendix 16 MEMO ...
Page 251: ...APPENDIXES Appendix 17 MEMO ...