7
SPECIAL ADJUSTMENT
7-6
3 Setting parameters #61 through #64
Specify the anti-resonance frequency obtained in step 2, to any of parameters #61 through #64*.
Control system setting parameters #61 through #64
No.
Name
Setting range
Initial value
Change
61
Anti-resonance frequency 0
5.0 to 200.0 [Hz]
(in 0.1 increments)
200.0
Always
62
Anti-resonance frequency 1
5.0 to 200.0 [Hz]
(in 0.1 increments)
200.0
Always
63
Anti-resonance frequency 2
5.0 to 200.0 [Hz]
(in 0.1 increments)
200.0
Always
64
Anti-resonance frequency 3
5.0 to 200.0 [Hz]
(in 0.1 increments)
200.0
Always
Up to four points can be specified through combination of anti-resonance frequency selection 0 and
anti-resonance frequency selection 1 of the CONT input signal.
The anti-resonance point may vary according to the arm length and the weight of the load.
In this case, assign this function to the CONT input signal among parameters 10 through 14 and switch
the anti-resonance frequency setting.
Anti-resonance frequency
selection 1
Anti-resonance frequency
selection 0
Anti-resonance frequency
OFF
OFF
Parameter #61*
OFF
ON
Parameter #62
ON
OFF
Parameter #63
ON
ON
Parameter #64
* These signals are assumed to be inactive at any time if they are not assigned to the
sequence input signals.
In this case, parameter #61 (anti-resonance frequency 0) is always valid.
To make anti-resonance frequency invalid, set the anti-resonance frequency at
200.0Hz.
Change the setting during stoppage because otherwise shocks may generate.
* Up to four points can be specified.
(a)
(b)
(c)
The anti-resonance frequency may vary
according to conditions a, b and c.
Summary of Contents for GYN101CAG-G09
Page 1: ...FUJI AC SERVO SYSTEM USER S MANUAL MEH395 ...
Page 2: ......
Page 10: ......
Page 20: ...1 Outline 1 10 MEMO ...
Page 21: ...2 1 Servomotor 2 2 Servo amplifier INSTALLATION ...
Page 32: ...2 INSTALLATION 2 12 MEMO ...
Page 46: ...3 WIRING 3 14 MEMO ...
Page 52: ...3 WIRING 3 20 MEMO ...
Page 64: ...3 WIRING 3 32 MEMO ...
Page 65: ...4 1 Test operation in two stages 4 2 First stage 4 3 Second stage TEST OPERATION ...
Page 70: ...4 TEST OPERATION 4 6 MEMO ...
Page 85: ...PARAMETERS 5 5 15 MEMO ...
Page 132: ...6 ADJUSTMENT OF SERVO 6 8 MEMO ...
Page 164: ...8 KEYPAD PANEL 8 18 MEMO ...
Page 186: ...9 INSPECTION AND MAINTENANCE 9 22 MEMO ...
Page 226: ...11SPECIFICATIONS 11 14 MEMO ...
Page 234: ...11SPECIFICATIONS 11 22 Servo amplifier Unit mm Unit mm Unit mm ...
Page 235: ...APPENDIXES Inertia moment calculation Load torque Timing chart ...
Page 250: ...APPENDIXES Appendix 16 MEMO ...
Page 251: ...APPENDIXES Appendix 17 MEMO ...