Suppresses mechanical vibrations to the maximum extent.
n
n
n
n
Equipped with a
“Damping Control Function”
which is an effective
countermeasure for vibration of the tips of robot arms, etc.
Fuji’s original damping control function (Patent pending)
In high tact operation of mechanisms with low rigidity, such as the tips of robot arms, suppression of arm tip
vibration is a major factor in shortening tact time. In the FALDIC-
β
series, Fuji’s original “Damping Control
Function” is standard equipment. It reduces vibration in machines with low rigidity and realizes high machine tact.
Without the damping control function
With the damping control function
Direction of
movement
Vibration waveform measured
by laser displacement gauge
2mm/div
2mm/div
500r/min/div
500r/min/div
Arm
vibration
Actual
speed
n
n
n
n
Equipped with a notch filter and servo analysis function.
Notch Filter
This function is for the purpose of reducing machine resonance. By setting the
data on the resonance point, which differs in each machine, as a parameter in the
servo amplifier, the machine resonance occurring in that point can be reduced.
Servo Analysis Function (Option)
In order to utilize the “Damping Control Function” and “Notch Filter,” etc.
effectively, it is necessary to analyze the “resonance frequencies” that are inherent
in each machine. If the “Servo Analysis Function” offered in the optional personal
computer loader is used, it can analyze the data for the machine system simply,
eliminating the needs for complicated calculations and adjustments which are
dependent on intuition.
Designed for high performance and high precision.
n
n
n
n
Instruction following servo
(positional deviation
≈≈≈≈
zero).
Position time is 1 ms or less.
Through the newly developed feed forward control which compensates for servo
delay, operation even during acceleration and deceleration can be done with
positional deviation almost zero. A positioning completed signal can be output
virtually simultaneously with the end of the instruction pulse (within 1 ms) .
n
n
n
n
16-bit High Resolution Encoder
A 65536 pulse/revolution serial encoder (exclusive INC) is standard equipment.
It can also be used for machines where high performance and highly accurate
positioning is required.
Feature. 2
Feature. 1
Direction of
movement
Vibration waveform measured
by laser displacement gauge
Arm
vibration
Actual
speed
Positional deviation
Instruction seed
ON
Positioning completed signal
1 ms or
less
ON
OFF
Summary of Contents for GYN101CAG-G09
Page 1: ...FUJI AC SERVO SYSTEM USER S MANUAL MEH395 ...
Page 2: ......
Page 10: ......
Page 20: ...1 Outline 1 10 MEMO ...
Page 21: ...2 1 Servomotor 2 2 Servo amplifier INSTALLATION ...
Page 32: ...2 INSTALLATION 2 12 MEMO ...
Page 46: ...3 WIRING 3 14 MEMO ...
Page 52: ...3 WIRING 3 20 MEMO ...
Page 64: ...3 WIRING 3 32 MEMO ...
Page 65: ...4 1 Test operation in two stages 4 2 First stage 4 3 Second stage TEST OPERATION ...
Page 70: ...4 TEST OPERATION 4 6 MEMO ...
Page 85: ...PARAMETERS 5 5 15 MEMO ...
Page 132: ...6 ADJUSTMENT OF SERVO 6 8 MEMO ...
Page 164: ...8 KEYPAD PANEL 8 18 MEMO ...
Page 186: ...9 INSPECTION AND MAINTENANCE 9 22 MEMO ...
Page 226: ...11SPECIFICATIONS 11 14 MEMO ...
Page 234: ...11SPECIFICATIONS 11 22 Servo amplifier Unit mm Unit mm Unit mm ...
Page 235: ...APPENDIXES Inertia moment calculation Load torque Timing chart ...
Page 250: ...APPENDIXES Appendix 16 MEMO ...
Page 251: ...APPENDIXES Appendix 17 MEMO ...