41S_Rev00
100
Questions and Troubleshooting
Splicing Operation
(1)
Error message appears on monitor
・
Refer to [Error Message List] function.
(2)
Inconsistent splice loss / High splice loss
・
Clean the V-grooves, fiber clamps, wind protector mirrors, and objective lenses.
・
Replace the electrodes.
・
“High Estimated Loss” error message section in the [Error Message List].
・
If the fiber has curl or bend memory, position the fiber so the crown (curve) of the memory is
turned downward.
・
The splice loss varies according to the cleave angle, arc conditions and fiber cleanliness.
・
If the splice loss is still too high or inconsistent after performing the above-mentioned
remedies, contact the authorized distributor Regular service (at least once a year) is
recommended to maintain high splicing quality.
(3)
Confirmation of splicing procedures
・
Refer to [Basic Operation] function.
(4)
Monitor suddenly turned off
・
The power saving function is automatically enabled when using a battery pack. The splicer
switches to the power saving state after an extended period of splicer inactivity. Press any
key to return to the normal state. To change the length of time before the splicer switches to
the power saving state, Refer to [Machine Settings] function.
(5)
Splicer power suddenly turned off without “Low Battery” message
・
The power saving function is automatically enabled when using a battery pack. The splicer
turns the splicer power off after an extended period of splicer inactivity. Press ON/OFF key
to turn on the splicer again. To change the length of time before the splicer turns the splicer
power off, section [Machine Settings] function.
(6)
Method to initialize arc condition of Splice mode
・
Refer to [Initialization in the edited parameter] in [Splice Menu].