41S_Rev00
75
Maintenance Menu
Clear Cleaver Counter
This function was the stored number of [Cleaver Counter] to be reset.
1.
Select the Clear Cleaver Counter icon.
2.
As the confirmation screen “Is it OK to clear?” appears, select “OK” key to clear.
It performs, after adjusting Cleaver who is using it.
Motor Drive
The some motors incorporated in the splicer can be manually operated individually. In the
course of splicing, the motors can also be operated by calling this menu in the [PAUSE], or
[FINISH] state.
1.
Select the Motor Drive icon.
2.
Pressing SET key changes motor selection. The name of the selected motor is
displayed in the upper section of the screen.
3.
Press Up/Down Arrow key to drive the motor in the desired direction.
Motor
Up Arrow key
Down Arrow key
ZL/ZR
Forward
Backward
X/Y
UP
DOWN
Parameter
Descriptions
Cleave Count
The number of times of cleave is
displayed.
Blade Position
The position of a blade is displayed.
Blade Height
The height of a blade is displayed.
When the motor reaches the limit of the operating range, the buzzer sounds
and the motor stops. Press the opposite arrow key to reverse and move the
motor again.
Display messages can be erased by pressing SET key. The message can be
displayed by pressing SET key again.
If the motor is moved too much with respect to the spliced fiber, the fiber may
break.